  Quantitative measurement of combustion gases in harsh environments using NDIR spectroscopy.

Niklas, C., Bauke, S., Müller, F., Golibrzuch, K., Wackerbarth, H., & Ctistis, G. (2019). Quantitative measurement of combustion gases in harsh environments using NDIR spectroscopy. Journal of Sensors and Sensor Systems, 8(1), 123-132. doi:10.5194/jsss-8-123-2019.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0003-17B5-7 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0003-17C7-3
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
3030683.pdf (出版社版), 4MB
ファイルのパーマリンク:
https://hdl.handle.net/21.11116/0000-0003-17C4-6
ファイル名:
3030683.pdf
説明:
-
OA-Status:
閲覧制限:
公開
MIMEタイプ / チェックサム:
application/pdf / [MD5]
技術的なメタデータ:
著作権日付:
-
著作権情報:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Niklas,, C., 著者
Bauke, S., 著者
Müller, F., 著者
Golibrzuch, K.1, 著者           
Wackerbarth, H., 著者
Ctistis, G., 著者
所属:
1Department of Dynamics at Surfaces, MPI for biophysical chemistry, Max Planck Society, ou_578600              

内容説明

表示:
非表示:
キーワード: -
 要旨: The global climate change calls for more environmentally friendly use of energy and has led to stricter limits and regulations for the emissions of various greenhouse gases. Consequently, there is nowadays an increasing need for the detection of exhaust and natural gases. This need leads to an ever-growing market for gas sensors, which, at the moment, is dominated by chemical sensors. Yet, the increasing demands to also measure under harsh environmental conditions pave the way for non-invasive measurements and thus optical detection techniques. Here, we present the development of two optical detection systems using non-dispersive infrared absorption spectroscopy (NDIR). One system is intended for civilian use, capable of detecting both CO as well as CO2 in the range of 4–5 µm. Furthermore, restrictions regarding size and economic viability are put on this sensor so it can compete with existing sensors. For CO2, an estimated resolution of 444 ppm is achieved, which is competitive with established sensors on the market. For CO an estimated resolution of 1401 ppm was achieved, rendering it necessary to improve this sensor to be competitive with other available sensors. The second system is used in an exhaust system and is capable of detecting CO2 at 3.2 µm facing cross-sensitivity with H2O. A data analysis method is described to separate the CO2 and H2O signals, revealing a time resolution of 33 µs.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2019-03-01
 出版の状態: オンラインで出版済み
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.5194/jsss-8-123-2019
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Journal of Sensors and Sensor Systems
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 8 (1) 通巻号: - 開始・終了ページ: 123 - 132 識別子(ISBN, ISSN, DOIなど): -