  Diffusion-weighted MRI of the prostate without susceptibility artifacts: Undersampled multi-shot turbo-STEAM with rotated radial trajectories.

Merrem, A., Hofer, S., Seif Amir Hosseini, A., Voit, D., Merboldt, K. D., Tan, Z., & Frahm, J. (2019). Diffusion-weighted MRI of the prostate without susceptibility artifacts: Undersampled multi-shot turbo-STEAM with rotated radial trajectories. NMR in Biomedicine, 32(5):. doi:10.1002/nbm.4074.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0003-1C85-8 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0003-7683-4
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
3031455.pdf (出版社版), 2MB
ファイルのパーマリンク:
https://hdl.handle.net/21.11116/0000-0003-7684-3
ファイル名:
3031455.pdf
説明:
-
OA-Status:
閲覧制限:
公開
MIMEタイプ / チェックサム:
application/pdf / [MD5]
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-
:
3031455_Suppl.tiff (付録資料), 7MB
ファイルのパーマリンク:
https://hdl.handle.net/21.11116/0000-0003-7685-2
ファイル名:
3031455_Suppl.tiff
説明:
-
OA-Status:
閲覧制限:
公開
MIMEタイプ / チェックサム:
image/tiff / [MD5]
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Merrem, A.1, 著者           
Hofer, S.1, 著者           
Seif Amir Hosseini, A., 著者
Voit, D.1, 著者           
Merboldt, K. D.1, 著者           
Tan, Z.1, 著者           
Frahm, J.1, 著者           
所属:
1Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society, ou_578634              

内容説明

表示:
非表示:
キーワード: Cancer; diffusion-weighted MRI; iterative reconstruction; prostate; radial sampling
 要旨: The aim of this study was to develop and evaluate a clinically feasible approach to diffusion-weighted (DW) MRI of the prostate without susceptibility-induced artifacts. The proposed method relies on an undersampled multi-shot DW turbo-STEAM sequence with rotated radial trajectories and a multi-step inverse reconstruction with denoised multi-shot phase maps. The total acquisition time was below 6 min for a resolution of 1.4 × 1.4 × 3.5 mm3 and six directions at b = 600 s mm-2 . Studies of eight healthy subjects and two patients with prostate cancer were performed at 3 T employing an 18-channel body-array coil and elements of the spine coil. The method was compared with conventional DW echo-planar imaging (EPI) of the prostate. The results confirm that DW STEAM MRI avoids geometric distortions and false image intensities, which were present for both single-shot EPI (ssEPI) and readout-segmented EPI, particularly near the intestinal wall of the prostate. Quantitative accuracy of the apparent diffusion coefficient (ADC) was validated with use of a numerical phantom providing ground truth. ADC values in the central prostate gland of healthy subjects were consistent with those measured using ssEPI and with literature data. Preliminary results for patients with prostate cancer revealed a correct anatomical localization of lesions with respect to T2 -weighted MRI in both mean DW STEAM images and ADC maps. In summary, DW STEAM MRI of the prostate offers clinically relevant advantages for the diagnosis of prostate cancer compared with state-of-the-art EPI-based approaches. The method warrants extended clinical trials.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2019-03-052019-05
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1002/nbm.4074
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: NMR in Biomedicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -