English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  The stray magnetic fields in Magnetic Resonance Current Density Imaging (MRCDI)

Göksu, C., Scheffler, K., Siebner, H., Thielscher, A., & Hanson, L. (2019). The stray magnetic fields in Magnetic Resonance Current Density Imaging (MRCDI). Physica Medica, 59, 142-150. doi:10.1016/j.ejmp.2019.02.022.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Göksu, C, Author           
Scheffler, K1, 2, Author           
Siebner, HR, Author
Thielscher, A, Author           
Hanson, LG, Author
Affiliations:
1Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              
2Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: Purpose
MR Current Density Imaging (MRCDI) involves weak current-injection into the head. The resulting magnetic field changes are measured by MRI. Stray fields pose major challenges since these can dominate the fields caused by tissue currents. We analyze the sources and influences of stray fields.
Methods

First, we supply validation data for a recently introduced MRCDI method with an unprecedented noise floor of ∼0.1 nT in vivo. Second, we assess the accuracy limit of the method and our corresponding cable current correction in phantoms ensuring high signal-to-noise ratio (SNR). Third, we simulate the influence of stray fields on current flow reconstructions for various realistic experimental set-ups. Fourth, we experimentally determine the physiological field variations. Finally, we explore the consequences of head positioning in an exemplary head coil, since off-center positioning provides space for limiting cable-induced fields.
Results

The cable correction method performs well except near the cables. Unless correcting for cable currents, the reconstructed current flow is easily misestimated by up to 45% for a realistic experimental set-up. Stray fields dominating the fields caused by tissue currents can occur, e.g. due to a wire segment 20 cm away from the imaged region, or due to a slight cable misalignment of 3°. The noise is increased by 40% due to physiological factors. Minor patient movements can cause field changes of ∼40 nT. Off-centered head positioning can locally reduce SNR by e.g. 30%.
Conclusions

Quantification of stray fields showed that MRCDI requires careful field correction. After cable correction, physiological noise is a limiting factor.

Details

show
hide
Language(s):
 Dates: 2019-03
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1016/j.ejmp.2019.02.022
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Physica Medica
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Elsevier
Pages: - Volume / Issue: 59 Sequence Number: - Start / End Page: 142 - 150 Identifier: ISSN: 1120-1797
CoNE: https://pure.mpg.de/cone/journals/resource/954928619268