English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  A step towards scan time minimisation: simultaneous multislice-accelerated diffusion-weighted imaging of the liver

Taron, J., Martirosian, P., Erb, M., Kuestner, T., Weiss, J., Notohamiprodjo, M., et al. (2016). A step towards scan time minimisation: simultaneous multislice-accelerated diffusion-weighted imaging of the liver. Insights into Imaging, 7(Supplement 1): B-0593, S289.

Item is

Basic

show hide
Genre: Meeting Abstract

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Taron, J, Author
Martirosian, P, Author
Erb, M1, Author           
Kuestner, T, Author
Weiss, J, Author
Notohamiprodjo, M, Author
Schwenzer, N, Author
Nikolaou, K, Author
Schraml, C, Author
Affiliations:
1external, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Purpose: To investigate the influence of different gradient preparation schemes and acceleration factors on acqusition time, image quality and quantitative parameters of simultaneous multislice-accelerated diffusion-weighted imaging of the liver in comparison to conventional sequences.
Methods and Materials: Respiratory-triggered simultaneous multislice diffusion-weighted imaging (sms-DWI) of the liver was performed at 1.5 T in ten healthy volunteers using a monopolar (MP) versus a bipolar (BP) gradient preparation with an sms-acceleration factor (AF) of 2 and 3 and compared to conventional diffusion-weighted images (c-DWI). Qualitative image analysis was carried out by two independent readers. Signal-to-noise ratios (SNR) and apparent diffusion coefficient (ADC) values were measured in a region-of-interest analysis. Total scan time was measured. The Kruskal-Wallis test followed by Steel-Dwass comparisons was executed for statistical analysis with p-values < 0.05 considered significant.
Results: Image quality in sms-DWI with AF2 was equivalenty high compared to c-DWI, with a reduction of scan time by 67%. AF3 resulted in only minor additional scan time reduction (by 69%) but was associated with a statistically significant deterioration of image quality. ADC values in sms-DWI were lower, SNR was higher as compared to c-DWI. Image quality was slightly higher using the MP diffusion preparation in sms-DWI and c-DWI.
Conclusion: Sms-DWI with an AF of 2 is a promising approach for scan time minimization while maintaining high image quality in DWI of the liver. The diffusion preparation did not significantly influence image quality in sms-DWI. The lower ADC values in sms-DWI should be considered in diagnostic reading studies.

Details

show
hide
Language(s):
 Dates: 2016-03
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1007/s13244-016-0475-8
 Degree: -

Event

show
hide
Title: European Congress of Radiology (ECR 2016)
Place of Event: Wien, Austria
Start-/End Date: 2016-03-02 - 2016-03-06

Legal Case

show

Project information

show

Source 1

show
hide
Title: Insights into Imaging
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 7 (Supplement 1) Sequence Number: B-0593 Start / End Page: S289 Identifier: ISSN: 1869-4101