  Erratum: Laser-Frequency Stabilization via a Quasimonolithic Mach-Zehnder Interferometer with Arms of Unequal Length and Balanced dc Readout [Phys. Rev. Applied 7, 024027 (2017)]

Gerberding, O., Isleif, K.-S., Mehmet, M., Danzmann, K., & Heinzel, G. (2018). Erratum: Laser-Frequency Stabilization via a Quasimonolithic Mach-Zehnder Interferometer with Arms of Unequal Length and Balanced dc Readout [Phys. Rev. Applied 7, 024027 (2017)]. Physical Review Applied, 9: 039902. doi:10.1103/PhysRevApplied.9.039902.

Item is

Basic

show hide
Item Permalink: http://hdl.handle.net/21.11116/0000-0003-5772-B Version Permalink: http://hdl.handle.net/21.11116/0000-0003-5773-A
Genre: Journal Article

Files

show Files
hide Files
:
PhysRevApplied.9.039902.pdf (Publisher version), 50KB
Name:
PhysRevApplied.9.039902.pdf
Description:
Open Access
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-

Locators

show

Creators

show
hide
 Creators:
Gerberding, Oliver1, Author              
Isleif, Katharina-Sophie1, Author              
Mehmet, Moritz1, Author              
Danzmann, Karsten1, Author              
Heinzel, Gerhard1, Author              
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Content

show
hide
Free keywords: Physics, Instrumentation and Detectors, physics.ins-det
 Abstract: Low frequency high precision laser interferometry is subject to excess laser frequency noise coupling via arm-length differences which is commonly mitigated by locking the frequency to a stable reference system. This is crucial to achieve picometer level sensitivities in the 0.1 mHz to 1 Hz regime, where laser frequency noise is usually high and couples into the measurement phase via arm-length mismatches in the interferometers. Here we describe the results achieved by frequency stabilising an external cavity diode laser to a quasi-monolithic unequal arm-length Mach-Zehnder interferometer read out at mid-fringe via balanced detection. This stabilisation scheme has been found to be an elegant solution combining a minimal number of optical components, no additional laser modulations and relatively low frequency noise levels. The Mach-Zehnder interferometer has been designed and constructed to minimise the influence of thermal couplings and to reduce undesired stray light using the optical simulation tool IfoCAD. We achieve frequency noise levels corresponding to LISA-like (laser interferometer space antenna) displacement sensitivities below 1 pm/$\sqrt{\textrm{Hz}}$ and are able to demonstrate the LISA frequency pre-stabilisation requirement of 300 Hz/$\sqrt{\textrm{Hz}}$ down to frequencies of 100 mHz by beating the stabilised laser with an Iodine locked reference.

Details

show
hide
Language(s):
 Dates: 2018
 Publication Status: Published in print
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Method: -
 Identifiers: DOI: 10.1103/PhysRevApplied.9.039902
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Physical Review Applied
  Abbreviation : Phys. Rev. Appl.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: College Park, Md. [u.a.] : American Physical Society
Pages: - Volume / Issue: 9 Sequence Number: 039902 Start / End Page: - Identifier: ISSN: 2331-7019
CoNE: /journals/resource/2331-7019