English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Detecting groups of coherent voxels in functional MRI data using spectral analysis and replicator dynamics

Müller, K., Neumann, J., Grigutsch, M., von Cramon, D., & Lohmann, G. (2007). Detecting groups of coherent voxels in functional MRI data using spectral analysis and replicator dynamics. Journal of Magnetic Resonance Imaging, 26(6), 1642-1650. doi:10.1002/jmri.21169.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Müller, K, Author
Neumann, J, Author
Grigutsch, M, Author
von Cramon, DY, Author
Lohmann, G1, Author           
Affiliations:
1External Organizations, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract:
Purpose

To investigate the relationship between functional MRI (fMRI) time series in the human brain, combining fMRI spectral analysis and replicator dynamics.
Materials and Methods

Simulated and real fMRI time courses were investigated using the bivariate spectral coherence. Coherence values were placed in coherence matrices encoding the relationship between the time courses. Groups of maximally coherent voxels were detected using replicator dynamics. Results were compared to a former approach called number of coherent voxels (NCV).
Results

NCV critically depends on a threshold that has to be chosen in advance. The lower this threshold, the larger the detected group. Using higher NCV thresholds in our simulations, the method did not detect all voxels that were constructed to have a high coherence among each other. In contrast, the replicator process found the whole group in all simulations.
Conclusion

The application of replicator dynamics to spectral matrices is a reliable method for detecting groups of maximally coherent voxels. A replicator process is able to determine groups of voxels with the property that each voxel in the group exhibits a high coherence with every other group member. In contrast to the NCV approach, this method is parameter‐free and does not require the a priori selection of a reference voxel.

Details

show
hide
Language(s): eng - English
 Dates: 2007-12
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1002/jmri.21169
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Magnetic Resonance Imaging
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Chicago, IL : Society for Magnetic Resonance Imaging
Pages: - Volume / Issue: 26 (6) Sequence Number: - Start / End Page: 1642 - 1650 Identifier: ISSN: 1053-1807
CoNE: https://pure.mpg.de/cone/journals/resource/954925594512