Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  On the error analyses of polarization measurements of the white-light coronagraph aboard ASO-S

Feng, L., Li, H., Inhester, B., Chen, B., Ying, B.-L., Lu, L., et al. (2019). On the error analyses of polarization measurements of the white-light coronagraph aboard ASO-S. Research in Astronomy and Astrophysics, 19(4): 059. doi:10.1088/1674-4527/19/4/59.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Feng, Li, Autor
Li, Hui, Autor
Inhester, Bernd1, Autor           
Chen, Bo, Autor
Ying, Bei-Li, Autor
Lu, Lei, Autor
Gan, Weiqun, Autor
Affiliations:
1Department Sun and Heliosphere, Max Planck Institute for Solar System Research, Max Planck Society, ou_1832289              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: The Advanced Space-based Solar Observatory (ASO-S) mission aims to explore the two most spectacular eruptions on the Sun: solar flares and coronal mass ejections (CMEs), and their magnetism. For the study of CMEs, the payload Lyman-alpha Solar Telescope (LST) has been proposed. It includes a traditional white-light coronagraph and a Lyman-alpha coronagraph which opens a new window to CME observations. Polarization measurements taken by white-light coronagraphs are crucial for deriving fundamental physical parameters of CMEs. To make such measurements, there are two options for a Stokes polarimeter which have been applied by existing white-light coronagraphs for space missions. One uses a single or triple linear polarizer, the other involves both a half-wave plate and a linear polarizer.We find that the former option is subject to less uncertainty in the derived Stokes vector propagating from detector noise. The latter option involves two plates which are prone to internal reflections and may have a reduced transmission factor. Therefore, the former option is adopted as our Stokes polarimeter scheme for LST. Based on the parameters of the intended linear polarizer(s) colorPol provided by CODIXX and the half-wave plate 2-APW-L2-012C by Altechna, it is further shown that the imperfect maximum transmittance of the polarizer significantly increases the variance amplification of Stokes vector by at least about 50% when compared with the ideal case. The relative errors of Stokes vector caused by the imperfection of colorPol polarizer and the uncertainty due to the polarizer assembly in the telescope are estimated to be about 5%. Among the considered parameters, we find that the dominant error comes from the uncertainty in the maximum transmittance of the polarizer.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2019
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1088/1674-4527/19/4/59
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Research in Astronomy and Astrophysics
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Institute of Physics Publishing (IOP)
Seiten: - Band / Heft: 19 (4) Artikelnummer: 059 Start- / Endseite: - Identifikator: ISSN: 1674-4527
CoNE: https://pure.mpg.de/cone/journals/resource/1674-4527