English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Feasibility of functional MRI at ultralow magnetic field via changes in cerebral blood volume

Buckenmaier, K., Pedersen, A., SanGiorgio, P., Scheffler, K., Clarke, J., & Inglis, B. (2019). Feasibility of functional MRI at ultralow magnetic field via changes in cerebral blood volume. Poster presented at 21st ISMAR - 15th EUROMAR Jount Conference (EUROISMAR 2019), Berlin, Germany.

Item is

Files

show Files

Creators

show
hide
 Creators:
Buckenmaier, K1, 2, Author           
Pedersen, A, Author
SanGiorgio, P, Author
Scheffler, K1, 2, Author           
Clarke, J, Author
Inglis, B, Author
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: We investigate the feasibility of performing functional MRI (fMRI) at ultralow field (ULF) with a Superconducting Quantum Interference Device (SQUID), as used for detecting magnetoencephalography (MEG) signals from the human head. While there is negligible magnetic susceptibility variation to produce blood oxygenation level-dependent (BOLD) contrast at ULF, changes in cerebral blood volume (CBV) may be a sensitive mechanism for fMRI given the five-fold spread in spin-lattice relaxation time (T1) values across the constituents of the human brain. We undertook simulations of functional signal strength for a simplified brain model involving activation of a primary cortical region in a manner consistent with a blocked task experiment. Our simulations involve measured values of T1 at ULF (130 μT) and experimental parameters for the performance of an ULFMRI scanner with a noise level of 0.1 fT/Hz-1/2 and a prepolarizing field of 200 mT. Under ideal experimental conditions we predict a functional signal-to-noise ratio of between 3.1 and 7.1 for an imaging time of 30 min, or between 1.5 and 3.5 for a blocked task experiment lasting 7.5 min. Our simulations suggest it may be feasible but challenging to perform fMRI using a ULFMRI system designed to perform MRI and MEG in situ.

Details

show
hide
Language(s):
 Dates: 2019-08
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: -
 Degree: -

Event

show
hide
Title: 21st ISMAR - 15th EUROMAR Jount Conference (EUROISMAR 2019)
Place of Event: Berlin, Germany
Start-/End Date: 2019-08-25 - 2019-08-30

Legal Case

show

Project information

show

Source 1

show
hide
Title: EUROISMAR 2019 Joint Conference
Source Genre: Proceedings
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: - Sequence Number: P552 Start / End Page: 758 Identifier: -