  A new hardware-software coil positioning system for interleaved TMS/fMRI: A motor cortex stimulation study

Moisa, M., Uludag, K., Ugurbil, K., & Thielscher, A. (2007). A new hardware-software coil positioning system for interleaved TMS/fMRI: A motor cortex stimulation study. Poster presented at 8th Conference of Tuebingen Junior Neuroscientists (NeNa 2007), Freudenstadt, Germany.

Item is

Basic

show hide
Item Permalink: http://hdl.handle.net/21.11116/0000-0003-ED4D-D Version Permalink: http://hdl.handle.net/21.11116/0000-0003-ED4E-C
Genre: Poster

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Moisa, M1, 2, Author              
Uludag, K1, 2, Author              
Ugurbil, K, Author
Thielscher, A1, 2, Author              
Affiliations:
1Former Department MRZ, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528700              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: An important practical challenge in interleaved TMS/fMRI is the accurate positioning of the coil inside the scanner. We describe a novel method which allows accurate coil placement inside the MR scanner using pre-planned coil positions previously determined with a neuronavigation system. The method was successfully used in a pilot study on the motorcortex which served to demonstrate the viability of our overall TMS/fMRI setup. Coil positions-of-interest are initially determined using a neuronavigation system (BrainView, Fraunhofer IPA, Stuttgart, Germany) and saved in respect to the coordinate system defined by a high-resolution T1 image. Inside the scanner, the position of the subject‘s head is determined using a fast FLASH image, which is automatically coregistred to the high resolution image. Based on the coregistered images, the software automatically determines the parameters for a coil holding device for targeting the pre-planned position. The accuracy of the method was tested in phantom measurements. Mean deviation between pre-planned coil positions marked on a spherical phantom and the position given by the setup was 3.895 mm. This demonstrates a good spatial accuracy in the range previously reported for offline neuronavigation systems1. In the pilot study, paired pulse TMS on the motor cortex was investigated in 6 subjects. Whole-brain echo planar images were acquired at 3T. The coil was positioned above the hot spot of the motor cortex (M1) which had previously been determined using the neuronavigation system. Subjects participated in four runs of supra motor threshold stimulation (120% MT), three runs at 80% MT stimulation and one run with volitional movement (acoustically triggered by pulses at 50% MT). A run took 8 minutes in which 27 paired pulses were applied. The group activation maps are in good concordance with previous findings2,3. In particular, for 120% MT stimulation, significant responses were observed in the primary auditory cortex, M1/S1, the supplementary & cingulate motor areas and the thalamus. The observed activation pattern showed robust overlap with the results of the volitional finger movements.

Details

show
hide
Language(s):
 Dates: 2007-11
 Publication Status: Published in print
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: -
 Degree: -

Event

show
hide
Title: 8th Conference of Tuebingen Junior Neuroscientists (NeNa 2007)
Place of Event: Freudenstadt, Germany
Start-/End Date: 2007-11-26 - 2007-11-28