Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Non-BOLD contrast for laminar fMRI in humans: CBF, CBV, and CMRO2

Huber, L., Uludağ, K., & Möller, H. E. (2019). Non-BOLD contrast for laminar fMRI in humans: CBF, CBV, and CMRO2. NeuroImage, 197, 742-760. doi:10.1016/j.neuroimage.2017.07.041.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Huber, Laurentius1, Autor
Uludağ, Kâmil2, Autor
Möller, Harald E.3, Autor           
Affiliations:
1National Institute of Mental Health, Bethesda, MD, USA, ou_persistent22              
2Maastricht Brain Imaging Center (M-BIC), Maastricht University, the Netherlands, ou_persistent22              
3Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Functional magnetic resonance imaging (fMRI) using the blood oxygenation level-dependent (BOLD) contrast indirectly probes neuronal activity changes via evoked cerebral blood flow (CBF), cerebral blood volume (CBV) and cerebral metabolic rate of oxygen (CMRO2) changes. The gradient-echo BOLD signal is mostly sensitive to ascending veins in the tissue and to pial veins. Thereby, the achievable spatial specificity to neuronal activation is limited. Furthermore, the non-linear interaction of CBF, CBV and CMRO2 can hamper quantitative interpretations of the BOLD signal across cortical depths with different baseline physiology. Measuring CBF, CBV or CMRO2 directly on a depth-dependent level has the potential to overcome these limitations. Here, we review these candidates of physiologically well-defined contrasts with the particular focus on arterial spin labeling (ASL), vascular space occupancy (VASO) and calibrated fMRI. These methods are reviewed with respect to their fMRI sequence parameter space and the applicability for neuroscientific studies in humans. We show representative results of depth-dependent ‘non-BOLD-fMRI’ in humans and their spatiotemporal characteristics. We conclude that non-BOLD methods are promising alternatives compared to conventional fMRI as they can provide improved spatial specificity, quantifiability and, hence, physiological interpretability as a function of cortical depth. At submillimeter resolution with inherently low signal-to-noise ratio (SNR), however, their use is still challenging. Nevertheless, we believe that ‘non-BOLD-fMRI’ is a useful alternative for depth-dependent investigations, by providing valuable insights into neurovascular coupling models that facilitate the interpretability of fMRI for neuroscientific applications.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2017-07-102017-02-092017-07-192017-07-202019-08-15
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1016/j.neuroimage.2017.07.041
Anderer: Epub 2017
PMID: 28736310
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden: ausblenden:
Projektname : -
Grant ID : ZIA-MH002783
Förderprogramm : Intramural Research Program
Förderorganisation : National Institute of Mental Health (NIMH)
Projektname : -
Grant ID : 452-11-002
Förderprogramm : Vidi-Grant
Förderorganisation : Netherlands Organisation for Scientific Research (NWO)
Projektname : Ultra-High Field Magnetic Resonance Imaging / HIMR
Grant ID : 316716
Förderprogramm : Funding Programme 7 (FP7-PEOPLE-2012-ITN)
Förderorganisation : European Commission (EC)
Projektname : -
Grant ID : HA-314
Förderprogramm : -
Förderorganisation : Helmholtz Alliance “ICEMED—Imaging and Curing Environmental Metabolic Diseases”

Quelle 1

einblenden:
ausblenden:
Titel: NeuroImage
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Orlando, FL : Academic Press
Seiten: - Band / Heft: 197 Artikelnummer: - Start- / Endseite: 742 - 760 Identifikator: ISSN: 1053-8119
CoNE: https://pure.mpg.de/cone/journals/resource/954922650166