日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Quantification of hydroxyl exchange of D‐Glucose at physiological conditions for optimization of glucoCEST MRI at 3, 7 and 9.4 Tesla

Zaiss, M., Anemone, A., Goerke, S., Longo, D., Herz, K., Pohmann, R., Aime, S., Rivlin, M., Navon, G., Golay, X., & Scheffler, K. (2019). Quantification of hydroxyl exchange of D‐Glucose at physiological conditions for optimization of glucoCEST MRI at 3, 7 and 9.4 Tesla. NMR in Biomedicine, 32(9), 1-14. doi:10.1002/nbm.4113.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0004-4BA1-2 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0004-7D45-3
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Zaiss, M1, 2, 著者           
Anemone, A, 著者
Goerke, S, 著者
Longo, DL, 著者
Herz, K1, 2, 著者           
Pohmann, R1, 2, 著者           
Aime, S, 著者
Rivlin, M, 著者
Navon, G, 著者
Golay, X, 著者
Scheffler, K1, 2, 著者           
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: Aims

To determine individual glucose hydroxyl exchange rates at physiological conditions and use this information for numerical optimization of glucoCEST/CESL preparation. To give guidelines for in vivo glucoCEST/CESL measurement parameters at clinical and ultra‐high field strengths.
Methods

Five glucose solution samples at different pH values were measured at 14.1 T at various B1 power levels. Multi‐B1‐Z‐spectra Bloch‐McConnell fits at physiological pH were further improved by the fitting of Z‐spectra of five pH values simultaneously. The obtained exchange rates were used in a six‐pool Bloch‐McConnell simulation including a tissue‐like water pool and semi‐solid MT pool with different CEST and CESL presaturation pulse trains. In vivo glucose injection experiments were performed in a tumor mouse model at 7 T.
Results and discussion

Glucose Z‐spectra could be fitted with four exchanging pools at 0.66, 1.28, 2.08 and 2.88 ppm. Corresponding hydroxyl exchange rates could be determined at pH = 7.2, T = 37°C and 1X PBS. Simulation of saturation transfer for this glucose system in a gray matter‐like and a tumor‐like system revealed optimal pulses at different field strengths of 9.4, 7 and 3 T. Different existing sequences and approaches are simulated and discussed. The optima found could be experimentally verified in an animal model at 7 T.
Conclusion

For the determined fast exchange regime, presaturation pulses in the spin‐lock regime (long recover time, short yet strong saturation) were found to be optimal. This study gives an estimation for optimization of the glucoCEST signal in vivo on the basis of glucose exchange rate at physiological conditions.

資料詳細

表示:
非表示:
言語:
 日付: 2019-072019-09
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/nbm.4113
eDoc: e4113
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: NMR in Biomedicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: London : Heyden & Son
ページ: - 巻号: 32 (9) 通巻号: - 開始・終了ページ: 1 - 14 識別子(ISBN, ISSN, DOIなど): ISSN: 0952-3480
CoNE: https://pure.mpg.de/cone/journals/resource/954925574973