Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  SENSE imaging with a quadrature half-volume transverse electromagnetic (TEM) coil at 4T

Avdievich, N., Peshkovsky, A., Kennan, R., & Hetherington, H. (2006). SENSE imaging with a quadrature half-volume transverse electromagnetic (TEM) coil at 4T. Journal of Magnetic Resonance Imaging, 24(4), 934-938. doi:10.1002/jmri.20714.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Avdievich, NI1, Autor           
Peshkovsky, AS, Autor
Kennan, RP, Autor
Hetherington, HP, Autor
Affiliations:
1External Organizations, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung:
Purpose

To demonstrate the feasibility of high‐field SENSE imaging of large objects, such as the human head, using a semicircular (half‐volume) coil for both transmission and multi‐channel reception.
Materials and Methods

As a proof of concept, we present experimental data obtained using a seven‐element half‐volume (180° of arc) transmit/receive quadrature transverse electromagnetic (TEM) coil. SENSE images of the human brain were acquired with a reduction factor of R = 2, using two degenerate linear modes of the same coil as independent receive channels at 4T. Since the need for additional hardware (i.e., a separate set of receive coils) is eliminated, the design can be substantially simplified.
Results

The experimental data demonstrate that linear modes of the half‐volume TEM coil have essentially no noise correlation, and their sensitivity profiles satisfy the requirement for small g‐factors. Also, this type of coil provides efficient transmission with a relatively large uniform region and a reception profile that is more uniform than that of the surface coils.
Conclusion

We demonstrate the feasibility of SENSE imaging using a half‐volume coil. Half‐volume coils allow reduced total power deposition compared to full‐volume coils, and may replace the latter in body imaging applications in which the target region of interest (ROI) is smaller than the entire torso.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2006-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/jmri.20714
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Magnetic Resonance Imaging
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Chicago, IL : Society for Magnetic Resonance Imaging
Seiten: - Band / Heft: 24 (4) Artikelnummer: - Start- / Endseite: 934 - 938 Identifikator: ISSN: 1053-1807
CoNE: https://pure.mpg.de/cone/journals/resource/954925594512