Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Luminescence Lifetime Imaging of Oxygen, pH, and carbon dioxide distribution using optical sensors

Liebsch, G., Klimant, I., Frank, B., Holst, G. A., & Wolfbeis, O. S. (2000). Luminescence Lifetime Imaging of Oxygen, pH, and carbon dioxide distribution using optical sensors. Applied Spectroscopy, 54(4), 548-559.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Holst_2000_1.pdf (Verlagsversion), 2MB
 
Datei-Permalink:
-
Name:
Holst_2000_1.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Eingeschränkt ( Max Planck Society (every institute); )
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Liebsch, Gregor , Autor
Klimant, Ingo , Autor
Frank, Bernhard , Autor
Holst, Gerhard A.1, Autor           
Wolfbeis, Otto S. , Autor
Affiliations:
1Department of Biogeochemistry, Max Planck Institute for Marine Microbiology, Max Planck Society, ou_2481693              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: We present a modular system for time-resolved two-dimensional luminescence lifetime imaging of planar optical chemical sensors. It is based on a fast, gateable charge-coupled device (CCD) camera without image intensifier and a pulsable light-emitting diode (LED) array as a light source. Software was developed for data acquisition with a maximum of parameter variability and for background suppression. This approach allows the operation of the system even under daylight. Optical sensors showing analyte-specific changes of their luminescence decay time were tested and used for sensing pO2, pCO2, pH, and temperature. The luminophores employed are either platinum(II)-porphyrins or ruthenium(II)-polypyridyl complexes, contained in polymer films, and can be efficiently excited by blue LEDs. The decay times of the sensor films vary from 70 μs for the Pt(II)-porphyrins to several 100 ns for the Ru(II) complexes. In a typical application, 7 mm-diameter spots of the respective optical sensor films were placed at the bottom of the wells of microtiterplates. Thus, every well represents a separate calibration chamber with an integrated sensor element. Both luminescence intensity-based and time-resolved images of the sensor spots were evaluated and compared. The combination of optical sensor technology with time-resolved imaging allows a determination of the distribution of chemical or physical parameters in heterogeneous systems and is therefore a powerful tool for screening and mapping applications.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2000-04-01
 Publikationsstatus: Erschienen
 Seiten: 12
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: -
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Applied Spectroscopy
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Frederick, Md. : Society for Applied Spectroscopy
Seiten: 12 Band / Heft: 54 (4) Artikelnummer: - Start- / Endseite: 548 - 559 Identifikator: ISSN: 0003-7028
CoNE: https://pure.mpg.de/cone/journals/resource/991042732725232