English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Luminescence Lifetime Imaging of Oxygen, pH, and carbon dioxide distribution using optical sensors

Liebsch, G., Klimant, I., Frank, B., Holst, G. A., & Wolfbeis, O. S. (2000). Luminescence Lifetime Imaging of Oxygen, pH, and carbon dioxide distribution using optical sensors. Applied Spectroscopy, 54(4), 548-559.

Item is

Files

show Files
hide Files
:
Holst_2000_1.pdf (Publisher version), 2MB
 
File Permalink:
-
Name:
Holst_2000_1.pdf
Description:
-
OA-Status:
Visibility:
Restricted ( Max Planck Society (every institute); )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Liebsch, Gregor , Author
Klimant, Ingo , Author
Frank, Bernhard , Author
Holst, Gerhard A.1, Author           
Wolfbeis, Otto S. , Author
Affiliations:
1Department of Biogeochemistry, Max Planck Institute for Marine Microbiology, Max Planck Society, ou_2481693              

Content

show
hide
Free keywords: -
 Abstract: We present a modular system for time-resolved two-dimensional luminescence lifetime imaging of planar optical chemical sensors. It is based on a fast, gateable charge-coupled device (CCD) camera without image intensifier and a pulsable light-emitting diode (LED) array as a light source. Software was developed for data acquisition with a maximum of parameter variability and for background suppression. This approach allows the operation of the system even under daylight. Optical sensors showing analyte-specific changes of their luminescence decay time were tested and used for sensing pO2, pCO2, pH, and temperature. The luminophores employed are either platinum(II)-porphyrins or ruthenium(II)-polypyridyl complexes, contained in polymer films, and can be efficiently excited by blue LEDs. The decay times of the sensor films vary from 70 μs for the Pt(II)-porphyrins to several 100 ns for the Ru(II) complexes. In a typical application, 7 mm-diameter spots of the respective optical sensor films were placed at the bottom of the wells of microtiterplates. Thus, every well represents a separate calibration chamber with an integrated sensor element. Both luminescence intensity-based and time-resolved images of the sensor spots were evaluated and compared. The combination of optical sensor technology with time-resolved imaging allows a determination of the distribution of chemical or physical parameters in heterogeneous systems and is therefore a powerful tool for screening and mapping applications.

Details

show
hide
Language(s): eng - English
 Dates: 2000-04-01
 Publication Status: Issued
 Pages: 12
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Applied Spectroscopy
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Frederick, Md. : Society for Applied Spectroscopy
Pages: 12 Volume / Issue: 54 (4) Sequence Number: - Start / End Page: 548 - 559 Identifier: ISSN: 0003-7028
CoNE: https://pure.mpg.de/cone/journals/resource/991042732725232