  Luminescence Lifetime Imaging of Oxygen, pH, and carbon dioxide distribution using optical sensors

Liebsch, G., Klimant, I., Frank, B., Holst, G. A., & Wolfbeis, O. S. (2000). Luminescence Lifetime Imaging of Oxygen, pH, and carbon dioxide distribution using optical sensors. Applied Spectroscopy, 54(4), 548-559.

Item is

Files

show Files
hide Files
:
Holst_2000_1.pdf (Publisher version), 2MB
 
File Permalink:
-
Name:
Holst_2000_1.pdf
Description:
-
OA-Status:
Visibility:
Restricted ( Max Planck Society (every institute); )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Liebsch, Gregor , Author
Klimant, Ingo , Author
Frank, Bernhard , Author
Holst, Gerhard A.1, Author           
Wolfbeis, Otto S. , Author
Affiliations:
1Department of Biogeochemistry, Max Planck Institute for Marine Microbiology, Max Planck Society, ou_2481693              

Content

show
hide
Free keywords: -
 Abstract: We present a modular system for time-resolved two-dimensional luminescence lifetime imaging of planar optical chemical sensors. It is based on a fast, gateable charge-coupled device (CCD) camera without image intensifier and a pulsable light-emitting diode (LED) array as a light source. Software was developed for data acquisition with a maximum of parameter variability and for background suppression. This approach allows the operation of the system even under daylight. Optical sensors showing analyte-specific changes of their luminescence decay time were tested and used for sensing pO2, pCO2, pH, and temperature. The luminophores employed are either platinum(II)-porphyrins or ruthenium(II)-polypyridyl complexes, contained in polymer films, and can be efficiently excited by blue LEDs. The decay times of the sensor films vary from 70 μs for the Pt(II)-porphyrins to several 100 ns for the Ru(II) complexes. In a typical application, 7 mm-diameter spots of the respective optical sensor films were placed at the bottom of the wells of microtiterplates. Thus, every well represents a separate calibration chamber with an integrated sensor element. Both luminescence intensity-based and time-resolved images of the sensor spots were evaluated and compared. The combination of optical sensor technology with time-resolved imaging allows a determination of the distribution of chemical or physical parameters in heterogeneous systems and is therefore a powerful tool for screening and mapping applications.

Details

show
hide
Language(s): eng - English
 Dates: 2000-04-01
 Publication Status: Issued
 Pages: 12
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Applied Spectroscopy
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Frederick, Md. : Society for Applied Spectroscopy
Pages: 12 Volume / Issue: 54 (4) Sequence Number: - Start / End Page: 548 - 559 Identifier: ISSN: 0003-7028
CoNE: https://pure.mpg.de/cone/journals/resource/991042732725232