Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  A Submicron Soft X-ray Active Grating Monochromator Beamline for Ultra-High Resolution Angle-Resolved Photoemission Spectroscopy

Tsai, H.-M., Fu, H.-W., Kuo, C.-Y., Huang, L.-J., Lee, C.-S., Hua, C.-Y., et al. (2019). A Submicron Soft X-ray Active Grating Monochromator Beamline for Ultra-High Resolution Angle-Resolved Photoemission Spectroscopy. AIP Conference Proceedings, 2054: 060047, pp. 1-6. doi:10.1063/1.5084678.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Tsai, Huang-Ming1, Autor
Fu, Huang-Wen1, Autor
Kuo, Chang-Yang2, Autor           
Huang, Liang-Jen1, Autor
Lee, Chang-Sheng1, Autor
Hua, Chih-Yu2, Autor           
Kao, Kai-Yang1, Autor
Lin, Hong-Ji1, Autor
Fung, Hok-Sum1, Autor
Chung, Shih-Chun1, Autor
Chang, Chun-Fu3, Autor           
Chainani, Ashish1, Autor
Tjeng, Liu Hao4, Autor           
Chen, Chien-Te1, Autor
Affiliations:
1External Organizations, ou_persistent22              
2Physics of Correlated Matter, Max Planck Institute for Chemical Physics of Solids, Max Planck Society, ou_1863445              
3Chun-Fu Chang, Physics of Correlated Matter, Max Planck Institute for Chemical Physics of Solids, Max Planck Society, ou_1863447              
4Liu Hao Tjeng, Physics of Correlated Matter, Max Planck Institute for Chemical Physics of Solids, Max Planck Society, ou_1863452              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: We have constructed a new soft X-ray beamlinc, namely the Taiwan Photon Source (TPS) 45A NSRRC-MP1 beamline, to facilitate suhmicron angle-resolved photoemission spectroscopy (ARPES) experiments with ultra-high energy resolution. The beamline uses an elliptically polarized undulator with 46 min magnet period (EPU46) that provides photon energies from 280 to 1500 eV with horizontal and vertical linear polarization, as well as left and right circular polarization. The vertical focusing mirror (VFM) and the active grating monochromator (AGM) utilize the novel 25-actuator optical surface bender developed for ultra-high resolution soft X-ray spectroscopies. With the surface slope error being reduced down to 0.03 jirad root-mean-square (mis) by the bender as verified by the long trace profiler (LIP) measurements, the ray-tracing simulation shows that an energy resolution of 5 meV can be achieved at 750 eV photon energy and the beam spot size can reach 0.5 jun x 0.4 tun at the sample position. By adjusting only the 6 actuators to control the surface major profile, our preliminary results show that the VFM is able to focus 70% of the photon flux from EPIJ46 through an entrance slit set at 1.9 1.un opening. As deduced from the measured ARPES data at the Fermi-level of Au, the energy resolving power of the monochromiitor \vas found to reach 34,000 full-width-half-miiximum (FWI1M) at 850 eV photon energy. By using the in-vacuum LTP measurement system cunently under development and all 25 actuators of the surface bender, we anticipate to further reduce greatly the intrinsic and thermal-induced slope errors of the VFM and AGM. It is feasible that the overall ARPES energy resolving power can reach the 140,000 target in the soft X-ray spectral region.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2019-06-012019-06-01
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1063/1.5084678
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: AIP Conference Proceedings
  Kurztitel : AIP Conf. Proc.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Melville, NY : AIP Publishing
Seiten: - Band / Heft: 2054 Artikelnummer: 060047 Start- / Endseite: 1 - 6 Identifikator: ISSN: 0094-243X
CoNE: https://pure.mpg.de/cone/journals/resource/954928528968