Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Intramyocellular lipid quantification from 1H long echo time spectra at 1.5 and 3 T by means of the LCModel technique

Škoch, A., Jírů, F., Dezortová, M., Krušinová, E., Kratochvílová, S., Pelikánová, T., et al. (2006). Intramyocellular lipid quantification from 1H long echo time spectra at 1.5 and 3 T by means of the LCModel technique. Journal of Magnetic Resonance Imaging, 23(5), 728-735. doi:10.1002/jmri.20574.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Škoch, A, Autor
Jírů, F, Autor
Dezortová, M, Autor
Krušinová, E, Autor
Kratochvílová, S, Autor
Pelikánová, T, Autor
Grodd, W1, Autor           
Hájek, M, Autor
Affiliations:
1External Organizations, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: PURPOSE:

To introduce a method of independent determination of CH2 and CH3 components of intramyocellular lipids (IMCLs) by using long TE for spectra measurement and LCModel for spectra evaluation, to test this technique in controls and insulin-resistant subjects, and to compare results at 1.5 and 3 T.
MATERIALS AND METHODS:

Eight healthy volunteers and 11 patients with type 2 diabetes mellitus underwent measurement using a 1.5-T MR scanner; six healthy volunteers were measured using a 3-T MR scanner. Spectra from the tibialis anterior muscle were acquired by using a point resolved spectroscopy (PRESS) sequence with the following parameters: TR/TE/ACQ = 2000 msec/270 msec/256. Spectra were processed by LCModel 6.1 software with two types of adopted basis-set.
RESULTS:

Spectra with good separation of both CH2 and CH3 components of IMCL and extramyocellular lipids (EMCLs) were obtained and the LCModel routine was successfully applied. The reproducibility comparison (N= 7 at 1.5 T vs. N = 5 at 3 T) showed that better results can be obtained at higher B0 values. The comparison of the healthy and insulin-resistant subjects proved that both IMCL_CH2/Cr and IMCL_CH3/Cr ratios significantly differ.
CONCLUSION:

Long TE spectroscopy of the human muscle with IMCL quantification using the LCModel technique can detect changes in IMCL levels as well as help in the study of fatty acyl chain composition. Using a higher field strength increased the intra-individual reproducibility by approximately 150%.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2006-05
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/jmri.20574
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Magnetic Resonance Imaging
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Chicago, IL : Society for Magnetic Resonance Imaging
Seiten: - Band / Heft: 23 (5) Artikelnummer: - Start- / Endseite: 728 - 735 Identifikator: ISSN: 1053-1807
CoNE: https://pure.mpg.de/cone/journals/resource/954925594512