Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Local variability of parameters for characterization of the corneal subbasal nerve plexus

Karsten, W., Scheibe, P., Köhler, B., Allgeier, S., Guthoff, R. F., & Stachs, O. (2016). Local variability of parameters for characterization of the corneal subbasal nerve plexus. Current Eye Research, 41(2), 186-198. doi:10.3109/02713683.2015.1010686.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Karsten, Winter1, Autor
Scheibe, Patrick1, Autor           
Köhler, Bernd, Autor
Allgeier, Stephan, Autor
Guthoff, Rudolf F., Autor
Stachs, Oliver, Autor
Affiliations:
1External Organizations, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Confocal laser scanning microscopy; Cornea; Nerve fiber quantification; Subbasal nerve plexus
 Zusammenfassung: Purpose: The corneal subbasal nerve plexus (SNP) offers high potential for early diagnosis of diabetic peripheral neuropathy. Changes in subbasal nerve fibers can be assessed in vivo by confocal laser scanning microscopy (CLSM) and quantified using specific parameters. While current study results agree regarding parameter tendency, there are considerable differences in terms of absolute values. The present study set out to identify factors that might account for this high parameter variability.

Materials and methods: In three healthy subjects, we used a novel method of software-based large-scale reconstruction that provided SNP images of the central cornea, decomposed the image areas into all possible image sections corresponding to the size of a single conventional CLSM image (0.16 mm2), and calculated a set of parameters for each image section. In order to carry out a large number of virtual examinations within the reconstructed image areas, an extensive simulation procedure (10,000 runs per image) was implemented.

Results: The three analyzed images ranged in size from 3.75 mm2 to 4.27 mm2. The spatial configuration of the subbasal nerve fiber networks varied greatly across the cornea and thus caused heavily location-dependent results as well as wide value ranges for the parameters assessed. Distributions of SNP parameter values varied greatly between the three images and showed significant differences between all images for every parameter calculated (p < 0.001 in each case).

Conclusions: The relatively small size of the conventionally evaluated SNP area is a contributory factor in high SNP parameter variability. Averaging of parameter values based on multiple CLSM frames does not necessarily result in good approximations of the respective reference values of the whole image area. This illustrates the potential for examiner bias when selecting SNP images in the central corneal area.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2014-05-262015-01-132015-02-242016
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.3109/02713683.2015.1010686
BibTex Citekey: Winter2016
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Current Eye Research
  Andere : Curr. Eye Res.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: London : IRL Press
Seiten: - Band / Heft: 41 (2) Artikelnummer: - Start- / Endseite: 186 - 198 Identifikator: ISSN: 0271-3683
CoNE: https://pure.mpg.de/cone/journals/resource/954925502198