English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  µOCT imaging using depth of focus extension by self-imaging wavefront division in a common-path fiber optic probe

Yin, B., Chu, K. K., Liang, C.-P., Singh, K., Reddy, R., & Tearney, G. (2016). µOCT imaging using depth of focus extension by self-imaging wavefront division in a common-path fiber optic probe. OPTICS EXPRESS, 24(5), 5555-5564. doi:10.1364/OE.24.005555.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Yin, Biwei1, Author
Chu, Kengyeh K.1, Author
Liang, Chia-Pin1, Author
Singh, Kanwarpal2, Author           
Reddy, Rohith1, Author
Tearney, Guillermo1, Author
Affiliations:
1external, ou_persistent22              
2External Organizations, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Optical coherence tomography (OCT) is an attractive medical modality due to its ability to acquire high-resolution, cross-sectional images inside the body using flexible, small-diameter, scanning fiber optic probes. Conventional, cross-sectional OCT imaging technologies have approximately 10-µ m axial resolution and 30-µ m lateral resolution, specifications that enable the visualization of microscopic architectural morphology. While this resolution is useful for many clinical applications, it is insufficient for resolving individual cells that characterize many diseases. To address this gap, a supercontinuum-laser-based, µ m-resolution OCT (µ OCT) system and a 500 µ m-diameter, extended depth of focus single fiber optic probe for endoscopic and intravascular imaging were designed and fabricated. At the distal tip of the fiber optic probe, a cylindrical waveguide was used to divide the wavefront to provide multiple circular propagation modes. Once transmitted through a relatively high NA lens (NA >0.1), these modes were projected as multiple coaxial foci (similar to 3 µ m full width at half maximum (FWHM)) over a greatly extended focal depth range. The distal tip of the probe also contained a common-path reference reflectance to minimize polarization and dispersion imbalances between sample and reference arm light. Measurements showed that the probe provides a 20-fold depth of focus extension, maintaining a 3-5 µ m lateral resolution (FWHM of PSF) and a 2 µ m axial resolution over a depth range of approximately 1 mm. These results suggest that this new optical configuration will be useful for achieving high-resolution, cross-sectional OCT imaging in catheter/endoscope-based medical imaging devices. (C) 2016 Optical Society of America

Details

show
hide
Language(s): eng - English
 Dates: 2016-03-07
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1364/OE.24.005555
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: OPTICS EXPRESS
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: 2010 MASSACHUSETTS AVE NW, WASHINGTON, DC 20036 USA : OPTICAL SOC AMER
Pages: - Volume / Issue: 24 (5) Sequence Number: - Start / End Page: 5555 - 5564 Identifier: ISSN: 1094-4087