日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Patient-specific RF safety assessment in MRI: Progress in creating surface-based human head and shoulder models

Kozlov, M., Kalloch, B., Horner, M., Bazin, P.-L., Weiskopf, N., & Möller, H. E. (2019). Patient-specific RF safety assessment in MRI: Progress in creating surface-based human head and shoulder models. In Brain and human body modeling: Computational human modeling at EMBC 2018 (pp. 245-282). Cham: Springer. doi:10.1007/978-3-030-21293-3_13.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0004-BC7F-B 版のパーマリンク: https://hdl.handle.net/21.11116/0000-000D-6164-5
資料種別: 書籍の一部

ファイル

表示: ファイル
非表示: ファイル
:
Kozlov_2019.pdf (出版社版), 3MB
ファイルのパーマリンク:
https://hdl.handle.net/21.11116/0000-0004-BC81-6
ファイル名:
Kozlov_2019.pdf
説明:
-
OA-Status:
閲覧制限:
公開
MIMEタイプ / チェックサム:
application/pdf / [MD5]
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Kozlov, Mikhail1, 著者                 
Kalloch, Benjamin2, 3, 著者           
Horner, Marc4, 著者
Bazin, Pierre-Louis1, 2, 5, 著者           
Weiskopf, Nikolaus1, 著者           
Möller, Harald E.6, 著者           
所属:
1Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_2205649              
2Department Neurology, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634549              
3Leipzig University of Applied Sciences, Germany, ou_persistent22              
4ANSYS, Inc., Evanston, IL, ou_persistent22              
5University of Amsterdam, the Netherlands, ou_persistent22              
6Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              

内容説明

表示:
非表示:
キーワード: Biomedical imaging; Computational electromagnetics; Antenna arrays; RF safety
 要旨: The interaction of electromagnetic (EM) fields with the human body during magnetic resonance imaging (MRI) is complex and subject specific. MRI radiofrequency (RF) coil performance and safety assessment typically includes numerical EM simulations with a set of human body models. The dimensions of mesh elements used for discretization of the EM simulation domain must be adequate for correct representation of the MRI coil elements, different types of human tissue, and wires and electrodes of additional devices. Examples of such devices include those used during electroencephalography, transcranial magnetic stimulation, and transcranial direct current stimulation, which record complementary information or manipulate brain states during MRI measurement. The electrical contact within and between tissues, as well as between an electrode and the skin, must also be preserved. These requirements can be fulfilled with anatomically correct surface-based human models and EM solvers based on unstructured meshes. Here, we report (i) our workflow used to generate the surface meshes of a head and torso model from the segmented AustinMan dataset, (ii) head and torso model mesh optimization for three-dimensional EM simulation in ANSYS HFSS, and (iii) several case studies of MRI RF coil performance and safety assessment.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2019-08-29
 出版の状態: オンラインで出版済み
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1007/978-3-030-21293-3_13
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Brain and human body modeling: Computational human modeling at EMBC 2018
種別: 書籍
 著者・編者:
所属:
出版社, 出版地: Cham : Springer
ページ: XI, 402 pp. 巻号: - 通巻号: - 開始・終了ページ: 245 - 282 識別子(ISBN, ISSN, DOIなど): DOI: 10.1007/978-3-030-21293-3
ISBN: 978-3-030-21292-6