Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Investigation of beam transmission in A 9SDH-2 3.0 MV NEC pelletron tandem accelerator

Deoli, N. T., Kummari, V. C., Pacheco, J. L., Duggan, J. L., Glass, G. A., McDaniel, F. D., et al. (2013). Investigation of beam transmission in A 9SDH-2 3.0 MV NEC pelletron tandem accelerator. AIP Conference Proceedings, 1525(1), 214-219. doi:10.1063/1.4802322.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Konferenzbeitrag

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Deoli, Naresh T.1, Autor
Kummari, Venkata C.1, Autor
Pacheco, Jose L.1, Autor
Duggan, Jerome L.1, Autor
Glass, Gary A.1, Autor
McDaniel, Floyd D.1, Autor
Reinert, Tilo1, Autor           
Rout, Bibhudutta1, Autor
Weathers, Duncan L.1, Autor
Affiliations:
1Ion Beam Modification And Analysis Laboratory, Department of Physics, University of North Texas, Denton, TX, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Electrostatic tandem accelerators are widely used to accelerate ions for experiments in materials science such as high energy ion implantation, materials modification, and analyses. Many applications require high beam current as well as high beam brightness at the target; thus, maximizing the beam transmission through such electrostatic accelerators becomes important. The Ion Beam Modification and Analysis Laboratory (IBMAL) at University of North Texas is equipped with four accelerators, one of which is a 9SDH-2 3.0 MV National Electrostatic Corporation (NEC) Pelletron® tandem accelerator. The tandem accelerator is equipped with three ion sources: one radio frequency-He ion source (Alphatross) and two ion sources of Cs-sputter type, the SNICS II (Source of Negative Ions by Cesium Sputtering) and a Cs-sputter source for trace-element accelerator based mass spectrometry. This work presents a detailed study of the beam transmission of hydrogen, silicon, and silver ions through the accelerator using the SNICS ion source with injection energies ranging from 20 keV to 70 keV. The beam transmission is quantified for three different terminal voltages: 1.5 MV, 2.0 MV and 2.5 MV. For a given terminal voltage, it has been found that beam transmission is strongly dependent on the ion source injector potential. Details of experiments and data analysis are presented.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2013-04-19
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1063/1.4802322
BibTex Citekey: Deoli:2013
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: AIP Conference Proceedings
  Kurztitel : AIP Conf. Proc.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Melville, NY : AIP Publishing
Seiten: - Band / Heft: 1525 (1) Artikelnummer: - Start- / Endseite: 214 - 219 Identifikator: ISSN: 0094-243X
CoNE: https://pure.mpg.de/cone/journals/resource/954928528968