  Rearranging a nanoprobe: Line foci, grid shadow patterns and performance tests

Rothermel, M., Butz, T., & Reinert, T. (2009). Rearranging a nanoprobe: Line foci, grid shadow patterns and performance tests. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 267(12-13), 2017-2020. doi:10.1016/j.nimb.2009.03.039.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Rothermel, Martin1, Author
Butz, Tilman1, Author
Reinert, Tilo1, Author           
Affiliations:
1Nukleare Festkörperphysik, University of Leipzig, Germany, ou_persistent22              

Content

show
hide
Free keywords: Nuclear microprobe; Alignment; Grid shadow; Performance
 Abstract: After a major modification of the target chamber at the Leipzig high energy ion nanoprobe the probe forming lens system, consisting of two separated quadrupole doublets, had been carefully realigned. This was done by adjusting the line foci position of each individual quadrupole on the centre position defined by the unfocused beam. Using a high magnification microscope the alignment process is very effective and precise. The lens system could be precisely realigned except an intrinsic rotational misalignment which is essentially reduced by a correction lens.

Grid shadow patterns have been taken and analysed in order to assess the characteristics of the system. The dominant aberrations are spherical with an additional parasitic octupole.

The grid shadow method is also very useful to determine the best position of the aperture diaphragms which minimizes the influence of the aberrations onto the beam spot size.

The rearrangement allowed larger aperture diaphragms for higher beam currents at a moderate increase in beam spot sizes. Performance tests yielded proton microbeam currents and half-widths of 4.5 nA at 1.5 μm, 8.3 nA at 1.5 μm and 17.2 nA at 2 μm. For high resolution work the expected beam spots around 0.3 μm at 100 pA were not achieved. The reason is very likely interference on the beam scanner, correlated in x- and y-direction, which results from the insufficiently rectified power supply voltage of the transconductance amplifier.

Details

show
hide
Language(s): eng - English
 Dates: 2009-03-132009-06-15
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1016/j.nimb.2009.03.039
BibTex Citekey: Rothermel:2009
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
  Abbreviation : NIM B
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : Elsevier B.V.
Pages: - Volume / Issue: 267 (12-13) Sequence Number: - Start / End Page: 2017 - 2020 Identifier: ISSN: 0168-583X