English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Localized B0 shimming based on 23Na MRI at 7 T

Gast, L., Henning, A., Hensel, B., Uder, M., & Nagel, A. (2020). Localized B0 shimming based on 23Na MRI at 7 T. Magnetic Resonance in Medicine, 83(4), 1339-1347. doi:10.1002/mrm.28011.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Gast, LV, Author
Henning, A1, 2, Author           
Hensel, B, Author
Uder, M, Author
Nagel, AM, Author
Affiliations:
1Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose: To validate the feasibility of localized B0 shimming based on B0 maps acquired with sodium (23Na) MRI.
Methods

A localized B0 shimming routine based on a constrained regularized algorithm in combination with 23Na MRI data acquired with a 3D density‐adapted radial readout scheme was implemented on a 7T MR system. Measurements were performed using a dual‐tuned 23Na/1H head coil. The quality of B0 maps reconstructed from 23Na images and the resulting shim values was examined depending on the acquisition duration between 10 minutes and 15 seconds to examine clinical applicability. The B0 shimming based on 23Na B0 maps was performed both for phantom and human head of 6 healthy volunteers, and the resulting B0 homogeneity was compared with the vendor‐provided 1H MRI–based gradient‐echo brain shimming routine.
Results

The proposed 23Na MRI–based shimming routine showed a reduction in B0 variation comparable to the vendor‐provided shim both in phantom and in vivo measurements. Within the examined multicompartment phantom, the B0 variations could be reduced by up to 77% using the 23Na MRI–based shim. In human head, B0 variations were reduced by approximately 50% using an acquisition time of 15 seconds for the 23Na B0 maps and only 1 iteration of B0 shimming.
Conclusion

The 23Na MRI–based localized B0 shimming is possible at 7 T within clinically acceptable acquisition durations (< 1 minute). It was shown that using the proposed 23Na MRI–based shimming approach, the 23Na image quality at ultrahigh field strength can be strongly improved.

Details

show
hide
Language(s):
 Dates: 2019-102020-04
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.28011
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 83 (4) Sequence Number: - Start / End Page: 1339 - 1347 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149