English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Results from the experimental evaluation of CeBr3 scintillators for 4He prompt gamma spectroscopy

Dal Bello, R., Martins, P. M., Graca, J., Hermann, G., Kihm, T., & Seco, J. (2019). Results from the experimental evaluation of CeBr3 scintillators for 4He prompt gamma spectroscopy. Medical Physics, 46(8), 3615-3626. doi:10.1002/mp.13594.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Dal Bello, Riccardo1, Author
Martins, Paulo Magalhaes1, Author
Graca, Joao1, Author
Hermann, German2, Author           
Kihm, T.3, Author           
Seco, Joao1, Author
Affiliations:
1external, ou_persistent22              
2Division Prof. Dr. James A. Hinton, MPI for Nuclear Physics, Max Planck Society, ou_2074298              
3Division Prof. Dr. Werner Hofmann, MPI for Nuclear Physics, Max Planck Society, ou_904550              

Content

show
hide
Free keywords: -
 Abstract: Purpose The presence of range uncertainties hinders the exploitation of the full potential of charged particle therapy. Several range verification techniques have been proposed to mitigate this limitation. Prompt gamma spectroscopy (PGS) is among the most promising solutions for online and in vivo range verification. In this work, we present the experimental results of the detection of prompt gamma radiation, induced by 4He beams at the Heidelberg Ion-Beam Therapy Center (HIT). The results were obtained, using a spectroscopic unit of which the design has been optimized using Monte Carlo simulations. Methods The spectroscopic unit is composed by a primary cerium bromide (CeBr3) crystal surrounded by a secondary bismuth germanate (BGO) crystal for anticoincidence detection (AC). The digitalization of the signals is performed with an advanced FADC/FPGA system. The 4He beams at clinical energies and intensities are delivered to multiple targets in the experimental cave at the HIT. We analyze the production of prompt gamma on oxygen and carbon targets, as well as high Z materials such as titanium and aluminum. The quantitative analysis includes a systematic comparison of the signal-to-noise ratio (SNR) improvement for the spectral lines when introducing the AC detection. Moreover, the SNR improvement could provide a reduction of the number of events required to draw robust conclusions. We perform a statistic analysis to determine the magnitude of such an effect. Results We present the energy spectra detected by the primary CeBr3 and the secondary BGO. The combination of these two detectors leads to an average increase of the signal-to-noise ratio by a factor 2.1, which confirms the Monte Carlo predictions. The spectroscopic unit is capable of detecting efficiently the discrete gamma emission over the full energy spectrum. We identify and analyze 19 independent spectral lines in an energy range spacing from E gamma=0.718 MeV to E gamma=6.13 MeV. Moreover, when introducing the AC detection, the number of events required to determine robustly the intensity of the discrete lines decreases. Finally, the analysis of the low-energy reaction lines determines whether a thin metal insert is introduced in the beam direction. Conclusions This work provides the experimental characterization of the spectroscopy unit in development for range verification through PGS at the HIT. Excellent performances have been demonstrated over the full prompt gamma energy spectrum with 4He beams at clinical energies and intensities.

Details

show
hide
Language(s):
 Dates: 2019-05-19
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mp.13594
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Medical Physics
  Other : Med. Phys.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York, etc. : Published for the American Association of Physicists in Medicine by the American Institute of Physics
Pages: - Volume / Issue: 46 (8) Sequence Number: - Start / End Page: 3615 - 3626 Identifier: ISSN: 0094-2405
CoNE: https://pure.mpg.de/cone/journals/resource/991042742884000