English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Dynamic glucose‐enhanced (DGE) MRI in the human brain at 7 T with reduced motion‐induced artifacts based on quantitative R1ρ mapping

Boyd, P., Breitling, J., Zimmermann, F., Korzowski, A., Zaiss, M., Schuenke, P., et al. (2020). Dynamic glucose‐enhanced (DGE) MRI in the human brain at 7 T with reduced motion‐induced artifacts based on quantitative R1ρ mapping. Magnetic Resonance in Medicine, 84(1), 182-191. doi:10.1002/mrm.28112.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Boyd, PS, Author
Breitling, J, Author
Zimmermann, F, Author
Korzowski, A, Author
Zaiss, M1, 2, Author           
Schuenke, P, Author
Weinfurtner, N, Author
Schlemmer, HP, Author
Ladd, ME, Author
Bachert, P, Author
Paech, D, Author
Goerke, S, Author
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose

Dynamic glucose‐enhanced (DGE)‐MRI based on chemical exchange‐sensitive MRI, that is, glucoCEST and gluco‐chemical exchange‐sensitive spin‐lock (glucoCESL), is intrinsically prone to motion‐induced artifacts because the final DGE contrast relies on the difference of images, which were acquired with a time gap of several mins. In this study, identification of different types of motion‐induced artifacts led to the development of a 3D acquisition protocol for DGE examinations in the human brain at 7 T with improved robustness in the presence of subject motion.
Methods

DGE‐MRI was realized by the chemical exchange‐sensitive spin‐lock approach based either on relaxation rate in the rotating frame (R1ρ)‐weighted or quantitative R1ρ imaging. A 3D image readout was implemented at 7 T, enabling retrospective volumetric coregistration of the image series and quantification of subject motion. An examination of a healthy volunteer without administration of glucose allowed for the identification of isolated motion‐induced artifacts.
Results

Even after coregistration, significant motion‐induced artifacts remained in the DGE contrast based on R1ρ‐weighted images. This is due to the spatially varying sensitivity of the coil and was found to be compensated by a quantitative R1ρ approach. The coregistered quantitative approach allowed the observation of a clear increase of the DGE contrast in a patient with glioblastoma, which did not correlate with subject motion.
Conclusion

The presented 3D acquisition protocol enables DGE‐MRI examinations in the human brain with improved robustness against motion‐induced artifacts. Correction of motion‐induced artifacts is of high importance for DGE‐MRI in clinical studies where an unambiguous assignment of contrast changes due to an actual change in local glucose concentration is a prerequisite.

Details

show
hide
Language(s):
 Dates: 2019-122020-07
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.28112
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 84 (1) Sequence Number: - Start / End Page: 182 - 191 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149