English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  First High-Precision Mass Measurements at PENTATRAP on highly charged Xe and Re ions

Schüssler, R. X. (2019). First High-Precision Mass Measurements at PENTATRAP on highly charged Xe and Re ions. PhD Thesis, Ruprecht-Karls-Universität, Heidelberg.

Item is

Files

show Files
hide Files
:
Dissertation_Rima_Schuessler.pdf (Any fulltext), 31MB
Name:
Dissertation_Rima_Schuessler.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Schüssler, Rima Xenia1, Author           
Blaum, Klaus, Referee
Pfeifer, Thomas, Referee
Affiliations:
1Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              

Content

show
hide
Free keywords: -
 MPINP: Präzisionsexperimente - Abteilung Blaum
 Abstract: The high-precision Penning-trap mass spectrometer Pentatrap was designed to perform
mass-ratio measurements of highly charged ions with relative uncertainties of 10−11. The
unique features of the Pentatrap experiment are the external ion sources providing
highly charged ions, the detection systems with single-ion sensitivity and especially the
stack of five Penning traps, which allows simultaneous measurements of single ions in
the traps. In the scope of this thesis, the first high-precision mass measurements with a
relative precision partially below δm/m ≈ 10−11 were performed. As a first benchmark
test, the mass differences of five xenon isotope pairs were determined. Comparison to
the literature values led to an improvement of the uncertainty of the mass differences of
a factor between 4 and 1700, in agreement with literature. In order to demonstrate the
accuracy of Pentatrap, the binding energy of the 37th electron in 132Xe was determined
as a proof-of-principle measurement by determining the mass difference of 132Xe17+ and
132Xe18+. The agreement of the result with theory allows performing stringent tests of
quantum electrodynamics using binding energies in ions with an even higher charge state
in the future. Lastly, the discovery of metastable electronic states in highly charged rhenium
and osmium ions by mass difference measurements, confirmed by theory, extends
the applicability of Penning-trap mass spectrometry to tests of atomic structure theories
and to the identification of long-lived excited states for a possible new generation of clocks
using highly charged ions.

Details

show
hide
Language(s):
 Dates: 2019-12-19
 Publication Status: Accepted / In Press
 Pages: 145 S. : Ill., graph. Darst.
 Publishing info: Heidelberg : Ruprecht-Karls-Universität
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.17617/2.3183485
 Degree: PhD

Event

show

Legal Case

show

Project information

show

Source

show