  Optimization of phase space files from clinical linear accelerators

Martins, J. C., Saxena, R., Neppl, S., Alhazmi, A., Reiner, M., Veloza, S., et al. (2019). Optimization of phase space files from clinical linear accelerators. Physica Medica, 64, 54-68. doi:10.1016/j.ejmp.2019.06.007.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Martins, Juliana Cristina, Author
Saxena, Rangoli1, Author           
Neppl, Sebastian, Author
Alhazmi, Abdulaziz, Author
Reiner, Michael, Author
Veloza, Stella, Author
Belka, Claus, Author
Parodi, Katia, Author
Affiliations:
1Department: Electrons-Photons-Neurons / Denk, MPI of Neurobiology, Max Planck Society, ou_1128546              

Content

show
hide
Free keywords: MONTE-CARLO SIMULATIONS; FOCAL SPOT SIZE; BEAM; ALGORITHM; HISTORYRadiology, Nuclear Medicine & Medical Imaging; Monte Carlo; Phase Space; Medical Linear Accelerator (linac);
 Abstract: This work proposes a methodology to produce an optimized phase-space (PhSp) for the Elekta Synergy linac by tuning the energy and direction of particles inside the 6-MV Elekta Precise PhSp, provided by the International Atomic Energy Agency (IAEA), for Monte Carlo (MC) simulations. First, the energies of the particles emerging from the original PhSp were increased by different factors, producing new PhSps. Percentage depth dose (PDD) profiles were simulated and compared to measured data from a Synergy linac for 6-MV photon beam. This process was repeated until a minimum difference was reached. Particles' directions were then manipulated following identified correlations to lateral profiles, resulting in two distinct perturbation factors based on inline and crossline profiles. Both factors were merged into one single optimal factor. For energy optimization, an increase of 0.32 MeV applied to all particles inside the original PhSp, but to 0.511 MeV annihilation photons, provided the best results. The direction optimization factor was the combination of the individual factors for inline (0.605%) and crossline (0.051%). The agreement between measured and simulated profiles, when using the optimized PhSp, improved considerably in comparison to simulations performed with the original IAEA PhSp. For all fields and depths analyzed, the discrepancies for PDD, inline and crossline profiles dropped from 11.2%, 15.7% and 27.5% to under 1.4%, 4.7% and 13.2%, respectively. The optimized PhSp should not replace the full linac modelling, however it offers an alternative for MC dose calculations when neither geometric details nor validated IAEA PhSp are available to the user.

Details

show
hide
Language(s): eng - English
 Dates: 2019-08-01
 Publication Status: Issued
 Pages: 15
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Physica Medica
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Elsevier
Pages: - Volume / Issue: 64 Sequence Number: - Start / End Page: 54 - 68 Identifier: ISSN: 1120-1797
CoNE: https://pure.mpg.de/cone/journals/resource/954928619268