Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  The Preparation and Preliminary Characterisation of Three Synthetic Andesite Reference Glass Materials (ARM-1, ARM-2, ARM-3) for In Situ Microanalysis

Wu, S., Worner, G., Jochum, K. P., Stoll, B., Simon, K., & Kronz, A. (2019). The Preparation and Preliminary Characterisation of Three Synthetic Andesite Reference Glass Materials (ARM-1, ARM-2, ARM-3) for In Situ Microanalysis. Geostandards and Geoanalytical Research, 43(4), 567-584. doi:10.1111/ggr.12301.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Wu, Shitou1, Autor
Worner, Gerhard1, Autor
Jochum, Klaus P.2, Autor           
Stoll, Brigitte2, Autor           
Simon, Klaus1, Autor
Kronz, Andreas1, Autor
Affiliations:
1external, ou_persistent22              
2Climate Geochemistry, Max Planck Institute for Chemistry, Max Planck Society, ou_2237635              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Three synthetic reference glasses were prepared by directly fusing and stirring 3.8 kg of high-purity oxide powders to provide reference materials for microanalytical work. These glasses have andesitic major compositions and are doped with fifty-four trace elements in nearly identical abundance (500, 50, 5 mu µg g−1) using oxide powders or element solutions, and are named ARM-1, 2 and 3, respectively. We further document that sector-field (SF) ICP-MS (Element 2 or Element XR) is capable of sweeping seventy-seven isotopes (from 7Li to 238U, a total of sixty-eight elements) in 1 s and, thus, is able to quantify up to sixty-eight elements by laser sampling. Micro- and bulk analyses indicate that the glasses are homogeneous with respect to major and trace elements. This paper provides preliminary data for the ARM glasses using a variety of analytical techniques (EPMA, XRF, ICP-OES, ICP-MS, LA-Q-ICP-MS and LA-SF-ICP-MS) performed in ten laboratories. Discrepancies in the data of V, Cr, Ni and Tl exist, mainly caused by analytical limitations. Preliminary reference and information values for fifty-six elements were calculated with uncertainties [2 relative standard error (RSE)] estimated in the range of 1-20%.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2019
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: ISI: 000496159300001
DOI: 10.1111/ggr.12301
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Geostandards and Geoanalytical Research
  Andere : Geostand. Geoanal. Res.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Vandoeuvre-lès-Nancy : Association scientifique pour la géologie et ses applications with the assistance of the Centre national de la recherche scientifique
Seiten: - Band / Heft: 43 (4) Artikelnummer: - Start- / Endseite: 567 - 584 Identifikator: ISSN: 1639-4488
CoNE: https://pure.mpg.de/cone/journals/resource/954925476486