English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Calibration of an airborne HOX instrument using the All Pressure Altitude based Calibrator for HOX Experimentation (APACHE)

Marno, D., Ernest, C., Hens, K., Javed, U., Klimach, T., Martinez, M., et al. (2019). Calibration of an airborne HOX instrument using the All Pressure Altitude based Calibrator for HOX Experimentation (APACHE). Atmospheric Measurement Techniques Discussions, in review.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Marno, Daniel1, Author           
Ernest, Cheryl, Author
Hens, Korbinian, Author
Javed, Umar, Author
Klimach, Thomas2, Author           
Martinez, Monica1, Author           
Rudolf, Markus1, Author           
Lelieveld, Jos1, Author           
Harder, Hartwig1, Author           
Affiliations:
1Atmospheric Chemistry, Max Planck Institute for Chemistry, Max Planck Society, ou_1826285              
2Particle Chemistry, Max Planck Institute for Chemistry, Max Planck Society, ou_1826291              

Content

show
hide
Free keywords: -
 Abstract: Laser induced fluorescence (LIF) is a widely used technique for both laboratory-based and ambient atmospheric chemistry measurements. However, LIF instruments require calibrations in order to translate instrument response into concentrations of chemical species. Calibration of LIF instruments measuring OH and HO2 (HOX), typically involves the photolysis of water vapor by 184.9 nm light thereby producing quantitative amounts of OH and HO2. For ground-based systems HOX instruments, this method of calibration is done at one pressure (typically ambient pressure) at the instrument inlet. However, airborne HOX instruments can experience varying cell pressures, internal residence times, temperatures, and humidity during flight. Therefore, replication of such variances when calibrating are essential to acquire the appropriate sensitivities. This requirement resulted in the development of the APACHE (All Pressure Altitude-based Calibrator for HOX Experimentation) chamber. It utilizes photolysis of water vapor, but has the additional ability to alter the pressure at the inlet of the HOX instrument thus relating instrument sensitivity to the external pressure ranges experienced during flight (275 to 1000 mbar). Measurements supported by COMSOL multiphysics and its computational fluid dynamics calculations revealed that, for all pressures explored in this study, APACHE is capable of initializing homogenous flow and maintain near uniform flow speeds across the internal cross-section of the chamber. This reduces the uncertainty regarding average exposure times across the mercury (Hg) UV ring lamp. Two different actinometrical approaches characterized the APACHE UV ring lamp flux as 6.3 x 1014 (± 0.9 x 1014) s-1 depending on pressure. Data presented in this study are the first direct calibrations, performed in a controlled environment using APACHE of an airborne HOX system instrument.

Details

show
hide
Language(s): eng - English
 Dates: 2019
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.5194/amt-2019-439
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Atmospheric Measurement Techniques Discussions
  Other : Atmos. Meas. Tech. Discuss.
  Abbreviation : AMTD
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Katlenburg-Lindau : Copernicus
Pages: - Volume / Issue: in review Sequence Number: - Start / End Page: - Identifier: ISSN: 1867-8610
CoNE: https://pure.mpg.de/cone/journals/resource/1867-8610