  Calibration of X-ray telescope prototypes at PANTER

Liao, Y.-Y., Shen, Z.-X., Yu, J., Huang, Q.-S., Ma, B., Zhang, Z., et al. (2019). Calibration of X-ray telescope prototypes at PANTER. Research in Astronomy and Astrophysics, 19(12): 172. doi:10.1088/1674–4527/19/12/172.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Calibration of X-ray telescope prototypes at PANTER.pdf (beliebiger Volltext), 7MB
 
Datei-Permalink:
-
Name:
Calibration of X-ray telescope prototypes at PANTER.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Privat
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Liao, Ying-Yu, Autor
Shen, Zheng-Xiang, Autor
Yu, Jun, Autor
Huang, Qiu-Shi, Autor
Ma, Bin, Autor
Zhang, Zhong, Autor
Wang, Xiao-Qiang, Autor
Wang, Kun, Autor
Xie, Chun, Autor
Burwitz, Vadim1, Autor           
Hartner, Gisela1, Autor           
La Caria, Marlis-Madeleine1, Autor           
Pelliciari, Carlo1, Autor           
Wang, Zhan-Shan, Autor
Affiliations:
1High Energy Astrophysics, MPI for Extraterrestrial Physics, Max Planck Society, ou_159890              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: We report on a ground X-ray calibration of two X-ray telescope prototypes at the PANTER X-ray Test Facility, operated by the Max-Planck-Institute for Extraterrestrial Physics, in Neuried, Germany. The X-ray telescope prototypes were developed by the Institute of Precision Optical Engineering (IPOE) of Tongji University, in a conical Wolter-I configuration, using thermal glass slumping technology. Prototype #1 with three layers and Prototype #2 with 21 layers were tested to assess the prototypes' on-axis imaging performance. The measurement of Prototype #1 indicates a Half Power Diameter (HPD) of 82'' at 1.49 keV. As for Prototype #2, we performed more comprehensive measurements of on-axis angular resolution and effective area at several energies ranging from 0.5–10 keV. The HPD and effective area are 111'' and 39 cm2 at 1.49 keV, respectively, at which energy the on-axis performance of the prototypes is our greatest concern.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2019-12
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1088/1674–4527/19/12/172
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Research in Astronomy and Astrophysics
  Alternativer Titel : Res. Astron. Astrophys.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 19 (12) Artikelnummer: 172 Start- / Endseite: - Identifikator: ISSN: 1674-4527