English
 
User Manual Privacy Policy Disclaimer Contact us
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Multi-parametric Artificial Neural Network Fitting of Phase-Cycled Balanced Steady-State Free Precession Data

Heule, R., Bause, J., Pusterla, O., & Scheffler, K. (2020). Multi-parametric Artificial Neural Network Fitting of Phase-Cycled Balanced Steady-State Free Precession Data. Magnetic Resonance in Medicine, Epub ahead. doi:10.1002/mrm.28325.

Item is

Basic

show hide
Item Permalink: http://hdl.handle.net/21.11116/0000-0006-792D-1 Version Permalink: http://hdl.handle.net/21.11116/0000-0006-792E-0
Genre: Journal Article

Files

show Files

Locators

show
hide
Description:
-

Creators

show
hide
 Creators:
Heule, R1, 2, Author              
Bause, J1, 2, Author              
Pusterla, O, Author
Scheffler, K1, 2, Author              
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose Standard relaxation time quantification using phase‐cycled balanced steady‐state free precession (bSSFP), eg, motion‐insensitive rapid configuration relaxometry (MIRACLE), is subject to a considerable underestimation of tissue T1 and T2 due to asymmetric intra‐voxel frequency distributions. In this work, an artificial neural network (ANN) fitting approach is proposed to simultaneously extract accurate reference relaxation times (T1, T2) and robust field map estimates ( urn:x-wiley:07403194:media:mrm28325:mrm28325-math-0001 , ΔB0) from the bSSFP profile. Methods Whole‐brain bSSFP data acquired at 3T were used for the training of a feedforward ANN with N = 12, 6, and 4 phase‐cycles. The magnitude and phase of the Fourier transformed complex bSSFP frequency response served as input and the multi‐parametric reference set [T1, T2, urn:x-wiley:07403194:media:mrm28325:mrm28325-math-0002 , ∆B0] as target. The ANN predicted relaxation times were validated against the target and MIRACLE. Results The ANN prediction of T1 and T2 for trained and untrained data agreed well with the reference, even for only four acquired phase‐cycles. In contrast, relaxometry based on 4‐point MIRACLE was prone to severe off‐resonance‐related artifacts. ANN predicted urn:x-wiley:07403194:media:mrm28325:mrm28325-math-0003 and ∆B0 maps showed the expected spatial inhomogeneity patterns in high agreement with the reference measurements for 12‐point, 6‐point, and 4‐point bSSFP phase‐cycling schemes. Conclusion ANNs show promise to provide accurate brain tissue T1 and T2 values as well as reliable field map estimates. Moreover, the bSSFP acquisition can be accelerated by reducing the number of phase‐cycles while still delivering robust T1, T2, urn:x-wiley:07403194:media:mrm28325:mrm28325-math-0004 , and ∆B0 estimates.

Details

show
hide
Language(s):
 Dates: 2020-06
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Method: -
 Identifiers: DOI: 10.1002/mrm.28325
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: Epub ahead Sequence Number: - Start / End Page: - Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149