Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  A novel method to measure T1-relaxation times of macromolecules and quantification of the macromolecular resonances

Murali-Manohar, S., Wright, A., Borbath, T., Avdievich, N., & Henning, A. (2021). A novel method to measure T1-relaxation times of macromolecules and quantification of the macromolecular resonances. Magnetic Resonance in Medicine, 85(2), 601-614. doi:10.1002/mrm.28484.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Murali-Manohar, S1, 2, Autor           
Wright, AM1, 2, Autor           
Borbath, T1, 2, Autor           
Avdievich, NI1, 2, Autor           
Henning, A1, 2, Autor           
Affiliations:
1Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose: Macromolecular peaks underlying metabolite spectra influence the quantification of metabolites. Therefore, it is important to understand the extent of contribution from macromolecules (MMs) in metabolite quantification. However, to model MMs more accurately in spectral fitting, differences in T1 relaxation times among individual MM peaks must be considered. Characterization of T1 -relaxation times for all individual MM peaks using a single inversion recovery technique is difficult due to eventual contributions from metabolites. On the contrary, a double inversion recovery (DIR) technique provided flexibility to acquire MM spectra spanning a range of longitudinal magnetizations with minimal metabolite influence. Thus, a novel method to determine T1 -relaxation times of individual MM peaks is reported in this work.

Methods: Extensive Bloch simulations were performed to determine inversion time combinations for a DIR technique that yielded adequate MM signal with varying longitudinal magnetizations while minimizing metabolite contributions. MM spectra were acquired using DIR-metabolite-cycled semi-LASER sequence. LCModel concentrations were fitted to the DIR signal equation to calculate T1 -relaxation times.

Results: T1 -relaxation times of MMs range from 204 to 510 ms and 253 to 564 ms in gray- and white-matter rich voxels respectively at 9.4T. Additionally, concentrations of 13 MM peaks are reported.

Conclusion: A novel DIR method is reported in this work to calculate T1 -relaxation times of MMs in the human brain. T1 -relaxation times and relaxation time corrected concentrations of individual MMs are reported in gray- and white-matter rich voxels for the first time at 9.4T.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2020-082021-02
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/mrm.28484
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York : Wiley-Liss
Seiten: - Band / Heft: 85 (2) Artikelnummer: - Start- / Endseite: 601 - 614 Identifikator: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149