Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Characterization of the detection chain of the Micro-channel X-ray Telescope

Ceraudo, F., Meuris, A., Doumayrou, E., Dumaye, L., Goetschy, A., Lavanant, T., et al. (2020). Characterization of the detection chain of the Micro-channel X-ray Telescope. Nuclear Instruments and Methods in Physics Research Section A, 973: 164164. doi:10.1016/j.nima.2020.164164.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Characterization of the detection chain of the Micro-channel X-ray Telescope.pdf (beliebiger Volltext), 2MB
 
Datei-Permalink:
-
Name:
Characterization of the detection chain of the Micro-channel X-ray Telescope.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Privat
MIME-Typ / Prüfsumme:
application/pdf
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Ceraudo, Francesco, Autor
Meuris, Aline, Autor
Doumayrou, Eric, Autor
Dumaye, Luc, Autor
Goetschy, Alain, Autor
Lavanant, Tony, Autor
Lortholary, Michel, Autor
Le Mer, Isabelle, Autor
Nico, François, Autor
Pinsard, Frédéric, Autor
Prieur, Marin, Autor
Renaud, Diana, Autor
Schneider, Benjamin, Autor
Tourrette, Thierry, Autor
Visticot, François, Autor
Meidinger, Norbert1, Autor           
Mießner, Danilo, Autor
Götz, Diego, Autor
Affiliations:
1High Energy Astrophysics, MPI for Extraterrestrial Physics, Max Planck Society, ou_159890              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: This paper describes the first performance tests and characterization of the detection chain of the Microchannel
X-ray Telescope (MXT), one of the instruments on board the French-Chinese mission SVOM for the
study of Gamma-Ray Bursts. The MXT detector consists of a back-illuminated 450 μm-thick fully-depleted framestore
silicon pnCCD, operating in the 0.2 − 10 keV energy range. Featuring an imaging area of ≈ 4 cm2, the
device is read out in parallel by two CAMEX ASICs and is powered and controlled by its dedicated Front-End
Electronics. A complete setup based on a cryostat and a multi-energy X-ray source have been designed for the
characterization of the detection chain. The tests, performed at ≈ −65 ◦C, demonstrate a spectral resolution of
(82 ± 2) eV at 1.5 keV as well as a < 200 eV low-level threshold. Both of those results are in compliance with
the performance requirements of the instrument.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2020-05-22
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1016/j.nima.2020.164164
Anderer: LOCALID: 3250759
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Nuclear Instruments and Methods in Physics Research Section A
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam : Elsevier B.V.
Seiten: - Band / Heft: 973 Artikelnummer: 164164 Start- / Endseite: - Identifikator: ISSN: 0168-9002
CoNE: https://pure.mpg.de/cone/journals/resource/954925485716