日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Comparative study of wound healing in rat skin following incision with a novel picosecond infrared laser (PIRL) and different surgical modalities

Petersen, H., Tavakoli, F., Kruber, S., Münscher, A., Gliese, A., Hansen, N.-O., Maier, S., Eggert, D., Robertson, W., Gosau, T., Sehner, S., Kwiatkowski, M., Schlüter, H., Schumacher, U., Knecht, R., & Miller, R. J. D. (2016). Comparative study of wound healing in rat skin following incision with a novel picosecond infrared laser (PIRL) and different surgical modalities. Lasers in Surgery and Medicine, 48(4), 385-391. doi:10.1002/lsm.22498.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0007-1038-8 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0007-1039-7
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
Petersen_et_al-2016-Lasers_in_Surgery_and_Medicine.pdf (出版社版), 893KB
ファイルのパーマリンク:
https://hdl.handle.net/21.11116/0000-0007-103A-6
ファイル名:
Petersen_et_al-2016-Lasers_in_Surgery_and_Medicine.pdf
説明:
This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
OA-Status:
閲覧制限:
公開
MIMEタイプ / チェックサム:
application/pdf / [MD5]
技術的なメタデータ:
著作権日付:
2016
著作権情報:
© the Author(s)

関連URL

表示:
非表示:
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Petersen, H.1, 著者
Tavakoli, F.1, 著者
Kruber, S.2, 著者
Münscher, A.1, 著者
Gliese, A.1, 著者
Hansen, N.-O.2, 著者
Maier, S.2, 3, 著者           
Eggert, D.4, 著者
Robertson, W.2, 著者
Gosau, T.5, 著者
Sehner, S.6, 著者
Kwiatkowski, M.7, 著者
Schlüter, H.7, 著者
Schumacher, U.5, 著者
Knecht, R.1, 著者
Miller, R. J. D.2, 著者
所属:
1Department of Otorhinolaryngology, Head and Neck Surgery and Oncology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany, ou_persistent22              
2Miller Group, Atomically Resolved Dynamics Department, Max Planck Institute for the Structure and Dynamics of Matter, Max Planck Society, ou_1938288              
3International Max Planck Research School for Ultrafast Imaging & Structural Dynamics (IMPRS-UFAST), Max Planck Institute for the Structure and Dynamics of Matter, Max Planck Society, ou_2266714              
4Heinrich-Pette-Institute, Leibnitz Institute of Experimental Virology, Hamburg, Germany, ou_persistent22              
5Department of Anatomy and Experimental Morphology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany, ou_persistent22              
6Department of Medical Biometry and Epidemiology, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany, ou_persistent22              
7Department of Clinical Chemistry, University Medical Center Hamburg-Eppendorf, Hamburg, Germany, ou_persistent22              

内容説明

表示:
非表示:
キーワード: animal model; electrosurgical device; electrosurgery; histology; laser surgery; scalpel
 要旨: Background and Objective: As a result of wound healing the original tissue is replaced by dysfunctional scar tissue. Reduced tissue damage during surgical procedures beneficially affects the size of the resulting scar and overall healing time. Thus the choice of a particular surgical instrument can have a significant influence on the postoperative wound healing. To overcome these problems of wound healing we applied a novel picosecond infrared laser (PIRL) system to surgical incisions. Previous studies indicated that negligible thermal, acoustic, or ionization stress effects to the surrounding tissue results in a superior wound healing.

Study Design/Materials and Methods: Using the PIRL system as a surgical scalpel, we performed a prospective wound healing study on rat skin and assessed its final impact on scar formation compared to the electrosurgical device and cold steel. As for the incisions, 6 full-thickness, 1-cm long-linear skin wounds were created on the dorsum of four rats using the PIRL, an electrosurgical device, and a conventional surgical scalpel, respectively. Rats were euthanized after 21 days of wound healing. The thickness of the subepithelial fibrosis, the depth and the transverse section of the total scar area of each wound were analyzed histologically.

Results: After 21 days of wound healing the incisions made by PIRL showed minor scar tissue formation as compared to the electrosurgical device and the scalpel. Highly significant differences (P < 0.001) were noted by comparing the electrosurgical device with PIRL and scalpel. The transverse section of the scar area also showed significant differences (P = 0.043) when comparing PIRL (mean: 141.46 mm2; 95%CI: 105.8–189.0 mm2) with scalpel incisions (mean: 206.82 mm2; 95%CI: 154.8–276.32 mm2). The subepithelial width of the scars that resulted from using the scalpel were 1.3 times larger than those obtained by using the PIRL (95%CI: 1.0–1.6) though the difference was not significant (P < 0.083).

Conclusions: The hypothesis that PIRL results in minimal scar formation with improved cosmetic outcomes was positively verified. In particular the resection of skin tumors or pathological scars, such as hypertrophic scars or keloids, are promising future fields of PIRL application.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2016-02-192016-03-04
 出版の状態: オンラインで出版済み
 ページ: 7
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1002/lsm.22498
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示: 非表示:
Project name : Contract grant sponsor: European Research Council; Contract grant number: ERC-AdG-2011-291630.
Grant ID : -
Funding program : -
Funding organization : -

出版物 1

表示:
非表示:
出版物名: Lasers in Surgery and Medicine
  省略形 : Lasers Surg Med
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Hoboken, NJ, USA : John Wiley & Sons
ページ: - 巻号: 48 (4) 通巻号: - 開始・終了ページ: 385 - 391 識別子(ISBN, ISSN, DOIなど): ISSN: 1096-9101
CoNE: https://pure.mpg.de/cone/journals/resource/1096-9101