English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  High-precision mass spectrometry of nobelium, lawrencium and rutherfordium isotopes and studies of long-lived isomers with SHIPTRAP

Kaleja, O. T. (2020). High-precision mass spectrometry of nobelium, lawrencium and rutherfordium isotopes and studies of long-lived isomers with SHIPTRAP. PhD Thesis, Johannes Gutenberg-Universität Mainz, Mainz.

Item is

Files

show Files
hide Files
:
kaleja,_oliver_thomas-high-precision-20200907180812325.pdf (Any fulltext), 20MB
Name:
kaleja,_oliver_thomas-high-precision-20200907180812325.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Kaleja, Oliver T.1, Author           
Block, Michael, Referee
Blaum, Klaus, Referee
Affiliations:
1Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              

Content

show
hide
Free keywords: -
 MPINP: Speichertechnik - Abteilung Blaum
 Abstract: In this work, the first successful application of the recently developed Phase-Imaging Ion-Cyclotron Resonance (PI-ICR) technique in the region of the heaviest elements is presented. For the first time, the atomic masses of several nobelium (No, Z=102), lawrencium (Lr, Z=103) and rutherfordium (Rf, Z=104) isotopes and isomers have been measured directly, reaching uncertainties on the order of few keV/c2 using the Penning-trap mass spectrometer SHIPTRAP. These heavy radionuclides were produced in fusion-evaporation reactions and separated from the primary beam by the velocity filter SHIP located at the GSI Helmholtz Centre for Heavy Ion Research in Darmstadt, Germany. The mass measurements were carried out at production rates of few ions per second down to few ions per minute. To improve the overall efficiency on stopped and thermalized ions, the recently developed cryogenic gas-stopping cell was implemented into the existing beam line. Its performance with respect to purity and efficiency has been characterized and improved. The overall efficiency of SHIPTRAP is increased by about one order of magnitude with respect to previous measurements on heavy ions.

Details

show
hide
Language(s):
 Dates: 2020-09-08
 Publication Status: Accepted / In Press
 Pages: xii, 148 Seiten
 Publishing info: Mainz : Johannes Gutenberg-Universität Mainz
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.17617/2.3254545
 Degree: PhD

Event

show

Legal Case

show

Project information

show

Source

show