  High‐precision stable isotope analysis of <5 μg CaCO3 samples by continuous‐flow mass spectrometry

Vonhof, H. B., De Graaf, S., Spero, H. J., Schiebel, R., Verdegaal, S. J. A., Metcalfe, B., et al. (2020). High‐precision stable isotope analysis of <5 μg CaCO3 samples by continuous‐flow mass spectrometry. Rapid Communications in Mass Spectrometry, 34(19): e8878. doi:10.1002/rcm.8878.

Item is

Basic

show hide
Genre: Journal Article

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Vonhof, Hubert B.1, Author              
De Graaf, Stefan1, Author              
Spero, Howard J.2, Author
Schiebel, Ralf1, Author              
Verdegaal, Suzan J. A.2, Author
Metcalfe, Brett2, Author
Haug, Gerald H.1, Author              
Affiliations:
1Climate Geochemistry, Max Planck Institute for Chemistry, Max Planck Society, ou_2237635              
2external, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Rationale Oxygen (δ18O) and carbon (δ13C) isotope analysis of foraminifera and other CaCO3 samples has been a key technique for paleoceanographical and paleoclimatological research for more than 60 years. There is ongoing demand for the analysis of ever smaller CaCO3 samples, driven, for example, by the desire to analyse single specimen planktic foraminifera, or small samples of tooth enamel. Methods We present a continuous‐flow mass spectrometric technique that uses cryo‐focusing of sample CO2 to analyse CaCO3 samples in a weight range between 10 and 3 μg. These are considerably lower sample weights than achievable on most currently available standard instrumentation. The technique is automated, so that sample throughput lies at >60 samples per day. The method involves an on‐line vial‐flushing routine designed to remove machine drift due to blank CO2 build‐up in the sample vials. Results In a series of experiments the effect of blank CO2 build‐up is quantified, and outgassing from the chlorobutyl septa identified as the source. An improved flushing routine together with the use of a cryo‐focusing step in the analysis is demonstrated to provide the analytical stability and sensitivity to analyse CaCO3 samples in a weight range between 10 and 3 μg at ≤0.1‰ precision (1σ) for both δ18O and δ13C values. The technique yields similarly precise results for the analysis of the structural carbonate fraction of small tooth enamel samples. Conclusions This study demonstrates that high‐precision oxygen and carbon isotope analysis is possible on CaCO3 samples smaller than 5 μg by use of a continuous‐flow isotope technique. Of key importance are (1) the application of a cold trap that drastically reduces sample gas loss, and (2) a modified flushing regime that eliminates increasing background CO2 build‐up in sample vials during longer automated sample runs.

Details

show
hide
Language(s): eng - English
 Dates: 2020-10-15
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: ISI: 000571215700007
DOI: 10.1002/rcm.8878
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Rapid Communications in Mass Spectrometry
  Other : Rapid Commun. Mass Spectrom.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York, NY : John Wiley & Sons
Pages: - Volume / Issue: 34 (19) Sequence Number: e8878 Start / End Page: - Identifier: ISSN: 0951-4198
CoNE: https://pure.mpg.de/cone/journals/resource/954925574961