English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Input polarization-independent polarization-sensitive optical coherence tomography using a depolarizer

Sharma, S., Hartl, G., Naveed, S. K., Blessing, K., Sharma, G., & Singh, K. (2020). Input polarization-independent polarization-sensitive optical coherence tomography using a depolarizer. Review of Scientific Instruments, 91(4): 043706. doi:10.1063/5.0001871.

Item is

Files

show Files
hide Files
:
5.0001871.pdf (Publisher version), 3MB
Name:
5.0001871.pdf
Description:
-
OA-Status:
Not specified
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).

Locators

show

Creators

show
hide
 Creators:
Sharma, Shivani1, Author
Hartl, Georg1, Author
Naveed, Sheeza K.1, Author
Blessing, Katharina2, Author           
Sharma, Gargi2, Author           
Singh, Kanwarpal2, 3, Author           
Affiliations:
1Department of Physics, Friedrich-Alexander Universität Erlangen-Nürnberg, Staudtstr. 7, 91058 Erlangen, Germany, ou_persistent22              
2Singh Research Group, Research Groups, Max Planck Institute for the Science of Light, Max Planck Society, ou_3164411              
3Max-Planck-Zentrum für Physik und Medizin, Max Planck Institute for the Science of Light, Max Planck Society, ou_3164414              

Content

show
hide
Free keywords: -
 Abstract: Polarization-sensitive optical coherence tomography is gaining attention because of its ability to diagnose certain pathological conditions at an early stage. The majority of polarization-sensitive optical coherence tomography systems require a polarization controller and a polarizer to obtain the optimal polarization state of the light at the sample. Such systems are prone to misalignment since any movement of the optical fiber normally coupled to the light source will change the polarization state of the incident beam. We propose and demonstrate an input polarization-independent polarization-sensitive optical coherence tomography system using a depolarizer that works for any input polarization state of the light source. The change in the optical power at the sample for arbitrary input polarized light for the standard polarization-sensitive optical coherence tomography system was found to be approximately 84% compared to 9% for our proposed method. The developed system was used to measure the retardance and optical axis orientation of a quarter-wave plate and the obtained values matched closely to the expectation. To further demonstrate the capability of measuring the birefringent properties of biological samples, we also imaged the nail bed. We believe that the proposed system is a robust polarization-sensitive optical coherence tomography system and that it will improve the diagnostic capabilities in clinical settings.

Details

show
hide
Language(s): eng - English
 Dates: 2020-01-202020-03-252020-04-10
 Publication Status: Published online
 Pages: 5
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1063/5.0001871
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Review of Scientific Instruments
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: AIP Publishing LLC
Pages: - Volume / Issue: 91 (4) Sequence Number: 043706 Start / End Page: - Identifier: -