Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  The FlashCam camera for CTA: trigger verification and fluorescence light detection capabilities

Sailer, S. (2020). The FlashCam camera for CTA: trigger verification and fluorescence light detection capabilities. PhD Thesis, Ruprecht-Karls-Universität, Heidelberg.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Hochschulschrift

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Sailer_Simon_PhD_Printed.pdf (beliebiger Volltext), 18MB
Name:
Sailer_Simon_PhD_Printed.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Sailer, Simon1, Autor           
Hinton, Jim, Gutachter
Quirrenbach, Andreas, Gutachter
Affiliations:
1Division Prof. Dr. James A. Hinton, MPI for Nuclear Physics, Max Planck Society, ou_2074298              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 MPINP: CTA - Abteilung Hinton
 Zusammenfassung: The next generation of Gamma-ray observatory - Cherenkov Telescope Array
(CTA) - aims at improving the detection capabilities at a broad energy range of
the gamma-ray spectrum by a factor of 10 in sensitivity. The FlashCam camera is
one of the camera types mounted on the medium-sized telescopes (MST) of CTA,
responsible for the observation of the core energy range between 150 GeV and
5 TeV. The first part of this thesis assumed the task of verifying the trigger system
of FlashCam. Studies of the trigger efficiency and night-sky background light
trigger response were performed, whilst also improving the Monte-Carlo
description of the detector. The second part was dedicated to the research of the
fluorescence light detection capabilities of the full 25 FlashCam-MST sub-array
using simulations. A trigger logic was developed, which allows the detection of
air showers with primary energies higher than 1 PeV through their fluorescence
emission. The effective area of this detection method was determined and the
angular resolution using a shower axis reconstruction calculated. The
combination of these individual studies allowed the estimation of the sensitivity
on point-like gamma-ray sources emitting in the energy range above 1 PeV.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2020-10-28
 Publikationsstatus: Angenommen
 Seiten: 140 S.
 Ort, Verlag, Ausgabe: Heidelberg : Ruprecht-Karls-Universität
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.17617/2.3265595
 Art des Abschluß: Doktorarbeit

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle

einblenden: