English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Electromagnetic simulation of a 16-channel head transceiver at 7 T using circuit-spatial optimization

Li, X., Pan, J., Avdievich, N., Hetherington, H., & Rispoli, J. (2021). Electromagnetic simulation of a 16-channel head transceiver at 7 T using circuit-spatial optimization. Magnetic Resonance in Medicine, 85(6), 3463-3478. doi:10.1002/mrm.28672.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Li, X, Author
Pan, JW, Author
Avdievich, NI1, 2, Author           
Hetherington, HP, Author
Rispoli, JV, Author
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose: With increased interest in parallel transmission in ultrahigh-field MRI, methods are needed to correctly calculate the S-parameters and complex field maps of the parallel transmission coil. We present S-parameters paired with spatial field optimization to fully simulate a double-row 16-element transceiver array for brain MRI at 7 T.

Methods: We implemented a closed-form equation of the coil S-parameters and overall spatial B+1
field. We minimized a cost function, consisting of coil S-parameters and the B+1 homogeneity in brain tissue, by optimizing transceiver components, including matching, decoupling circuits, and lumped capacitors. With this, we are able to compare the in silico results determined with and without B+1 homogeneity weighting. Using the known voltage range from the host console, we reconstructed the B+1

maps of the array and performed RF shimming with four realistic head models.

Results: As performed with B+1
homogeneity weighting, the optimized coil circuit components were highly consistent over the four heads, producing well-tuned, matched, and decoupled coils. The mean peak forward powers and B+1 statistics for the head models are consistent with in vivo human results (N = 8). There are systematic differences in the transceiver components as optimized with or without B+1 homogeneity weighting, resulting in an improvement of 28.4 ± 7.5% in B+1

homogeneity with a small 1.9 ± 1.5% decline in power efficiency.

Conclusion: This co-simulation methodology accurately simulates the transceiver, predicting consistent S-parameters, component values, and B+1
field. The RF shimming of the calculated field maps match the in vivo performance.

Details

show
hide
Language(s):
 Dates: 2021-022021-06
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.28672
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 85 (6) Sequence Number: - Start / End Page: 3463 - 3478 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149