Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  A laser temperature jump apparatus based on commercial parts equipped with highly sensitive spectrophotometric detection

Bremer, C., Bergbauer, R., Ruf, H., Bannister, J. J., & Grell, E. (1993). A laser temperature jump apparatus based on commercial parts equipped with highly sensitive spectrophotometric detection. Measurement Science and Technology, 4(12), 1385-1393. doi:10.1088/0957-0233/4/12/013.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Bremer, Christoph1, Autor           
Bergbauer, Rolf2, Autor           
Ruf, Horst1, Autor           
Bannister, John J.3, Autor
Grell, Ernst1, Autor           
Affiliations:
1Molecular Biophysics Group, Max Planck Institute of Biophysics, Max Planck Society, ou_3264820              
2Max Planck Institute of Biophysics, Max Planck Society, ou_2068288              
3Medioption Ltd., Richmond House, Manchester M1 3HZ, UK, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: A temperature jump apparatus is described which is based mainly on commercially available components. Temperature jumps of about 2 degrees C in about 150 µl of aqueous solutions can be produced within 10 µs by absorption of the infrared radiation of a pulsed atomic iodine laser. The time range available for kinetic experiments is about 30 µs to 1s. The necessary modifications of the commercial iodine laser are discussed. A prominent feature of the apparatus is the very high sensitivity of the spectrophotometric detection system in the visible spectral range. Signal-to-noise ratios of up to 2x104 are reached at a time resolution of 1 µs. A method is described to determine the size of the temperature jump of each individual experiment. Thus not only the relaxation times, which are independent of the size of small temperature jumps, can be evaluated but also the corresponding relaxation amplitudes can be determined in a precise manner. Furthermore, an effective method to recycle the laser medium i-C3F7I is described.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 1993-06-101993-08-171993-12-01
 Publikationsstatus: Erschienen
 Seiten: 10
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1088/0957-0233/4/12/013
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Measurement Science and Technology
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Bristol : IOP Pub.
Seiten: - Band / Heft: 4 (12) Artikelnummer: - Start- / Endseite: 1385 - 1393 Identifikator: ISSN: 0957-0233
CoNE: https://pure.mpg.de/cone/journals/resource/954927547263