English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Time-resolved response of fluorescent alkali ion indicators and detection of short-lived intermediates upon binding to molecular cavities

Doludda, M., Kastenholz, F., Lewitzki, E., & Grell, E. (1996). Time-resolved response of fluorescent alkali ion indicators and detection of short-lived intermediates upon binding to molecular cavities. Journal of Fluorescence, 6(3), 159-163. doi:10.1007/BF00732055.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Doludda, Michael1, Author           
Kastenholz, Frank1, Author           
Lewitzki, Erwin1, Author           
Grell, Ernst1, Author           
Affiliations:
1Department of Biophysical Chemistry, Max Planck Institute of Biophysics, Max Planck Society, ou_2068289              

Content

show
hide
Free keywords: Alkali ion indicators; cryptands; fluorocryptands; fluorescence-stopped flow; cation binding mechanism; intermediate state detection
 Abstract: Stopped-flow kinetic studies have been performed to determine the kinetic parameters of K+ binding to the fluorescent cryptand F222 and of Na+ binding to F221 at pH 8.O. The results clearly indicate that a comparatively stable intermediate is formed before the rate-limiting binding step occurs with a rate constant around 30 s-1 under the chosen experimental conditions. The conversion of the intermediate to the final cation complex is assigned to the final penetration of the already bound, but still partially solvated cation into the ligand's cavity. The main fluorescence intensity change found upon cation binding is attributed to the second reaction step, and not to the fast, initial binding reaction. The comparatively slow overall binding reaction is interpreted on the bases of a special solvate substitution mechanism which, in principle, can also account for the 1500 times slower binding of Ca2+ to F221. With regard to time-resolved analytical Na+ and K+ determinations, the response times under the chosen conditions are around 20 ms. Differentiation between Na+ and Ca2+, for example, is possible with F221 on the basis of completely different response times.

Details

show
hide
Language(s): eng - English
 Dates: 1995-09-241996-06-291996-09-01
 Publication Status: Issued
 Pages: 5
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1007/BF00732055
PMID: 24227204
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Fluorescence
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York, NY : Kluwer Academic/Plenum Publishers
Pages: - Volume / Issue: 6 (3) Sequence Number: - Start / End Page: 159 - 163 Identifier: ISSN: 1053-0509
CoNE: https://pure.mpg.de/cone/journals/resource/954925594506