  Whole-brain quantitative CEST MRI at 7T using parallel transmission methods and B+1 correction

Liebert, A., Tkotz, K., Herrler, J., Linz, P., Mennecke, A., German, A., et al. (2021). Whole-brain quantitative CEST MRI at 7T using parallel transmission methods and B+1 correction. Magnetic Resonance in Medicine, 86(1), 346-362. doi:10.1002/mrm.28745.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Liebert, A, Autor
Tkotz, K, Autor
Herrler, J, Autor
Linz, P, Autor
Mennecke , A, Autor
German, A, Autor
Liebig , P, Autor
Gumbrecht , R, Autor
Schmidt, M, Autor
Doerfler, A, Autor
Uder, M, Autor
Zaiss, M1, 2, Autor           
Nagel, AM, Autor
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose: To enable whole-brain quantitative CEST MRI at ultra-high magnetic field strengths (B0 ≥ 7T) within short acquisition times.

Methods: Multiple interleaved mode saturation (MIMOSA) was combined with fast online-customized (FOCUS) parallel transmission (pTx) excitation pulses and B+1
correction to achieve homogenous whole-brain coverage. Examinations of 13 volunteers were performed on a 7T MRI system with 3 different types of pulse sequences: (1) saturation in circular polarized (CP) mode and CP mode readout, (2) MIMOSA and CP readout, and (3) MIMOSA and FOCUS readout. For comparison, the inverse magnetic transfer ratio metric for relayed nuclear Overhauser effect and amide proton transfer were calculated. To investigate the number of required acquisitions for a good B+1

correction, 4 volunteers were measured with 6 different B1 amplitudes. Finally, time point repeatability was investigated for 6 volunteers.

Results: MIMOSA FOCUS sequence using B+1
correction, with both single and multiple points, reduced inhomogeneity of the CEST contrasts around the occipital lobe and cerebellum. Results indicate that the most stable inter-subject coefficient of variation was achieved using the MIMOSA FOCUS sequence. Time point repeatability of MIMOSA FOCUS with single-point B+1

correction showed a maximum coefficient of variation below 8% for 3 measurements in a single volunteer.

Conclusion: A combination of MIMOSA FOCUS with a single-point B+1
correction can be used to achieve quantitative CEST measurements at ultra-high magnetic field strengths. Compared to previous B+1 correction methods, acquisition time can be reduced as additional scans required for B+1 correction can be omitted.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2021-022021-07
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/mrm.28745
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York : Wiley-Liss
Seiten: - Band / Heft: 86 (1) Artikelnummer: - Start- / Endseite: 346 - 362 Identifikator: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149