English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Whole-brain quantitative CEST MRI at 7T using parallel transmission methods and B+1 correction

Liebert, A., Tkotz, K., Herrler, J., Linz, P., Mennecke, A., German, A., et al. (2021). Whole-brain quantitative CEST MRI at 7T using parallel transmission methods and B+1 correction. Magnetic Resonance in Medicine, 86(1), 346-362. doi:10.1002/mrm.28745.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Liebert, A, Author
Tkotz, K, Author
Herrler, J, Author
Linz, P, Author
Mennecke , A, Author
German, A, Author
Liebig , P, Author
Gumbrecht , R, Author
Schmidt, M, Author
Doerfler, A, Author
Uder, M, Author
Zaiss, M1, 2, Author           
Nagel, AM, Author
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose: To enable whole-brain quantitative CEST MRI at ultra-high magnetic field strengths (B0 ≥ 7T) within short acquisition times.

Methods: Multiple interleaved mode saturation (MIMOSA) was combined with fast online-customized (FOCUS) parallel transmission (pTx) excitation pulses and B+1
correction to achieve homogenous whole-brain coverage. Examinations of 13 volunteers were performed on a 7T MRI system with 3 different types of pulse sequences: (1) saturation in circular polarized (CP) mode and CP mode readout, (2) MIMOSA and CP readout, and (3) MIMOSA and FOCUS readout. For comparison, the inverse magnetic transfer ratio metric for relayed nuclear Overhauser effect and amide proton transfer were calculated. To investigate the number of required acquisitions for a good B+1

correction, 4 volunteers were measured with 6 different B1 amplitudes. Finally, time point repeatability was investigated for 6 volunteers.

Results: MIMOSA FOCUS sequence using B+1
correction, with both single and multiple points, reduced inhomogeneity of the CEST contrasts around the occipital lobe and cerebellum. Results indicate that the most stable inter-subject coefficient of variation was achieved using the MIMOSA FOCUS sequence. Time point repeatability of MIMOSA FOCUS with single-point B+1

correction showed a maximum coefficient of variation below 8% for 3 measurements in a single volunteer.

Conclusion: A combination of MIMOSA FOCUS with a single-point B+1
correction can be used to achieve quantitative CEST measurements at ultra-high magnetic field strengths. Compared to previous B+1 correction methods, acquisition time can be reduced as additional scans required for B+1 correction can be omitted.

Details

show
hide
Language(s):
 Dates: 2021-022021-07
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.28745
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 86 (1) Sequence Number: - Start / End Page: 346 - 362 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149