日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Improving the quality of electron tomography image volumes using pre-reconstruction filtering

Maiorca, M., Hanssen, E., Kazmierczak, E., Maco, B., Kudryashev, M., Hall, R., Quiney, H., & Tilley, L. (2012). Improving the quality of electron tomography image volumes using pre-reconstruction filtering. Journal of Structural Biology, 180(1), 132-142. doi:10.1016/j.jsb.2012.05.019.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-0008-12D3-5 版のパーマリンク: https://hdl.handle.net/21.11116/0000-0008-12D4-4
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Maiorca, Mauro1, 2, 著者
Hanssen, Eric2, 3, 著者
Kazmierczak, Edmund4, 著者
Maco, Bohumil5, 著者
Kudryashev, Misha6, 著者           
Hall, Richard7, 著者
Quiney, Harry2, 8, 著者
Tilley, Leann1, 2, 著者
所属:
1Department of Biochemistry and Molecular Biology, Bio21 Molecular Science and Biotechnology Institute, The University of Melbourne, Melbourne, Vic. 3010, Australia, ou_persistent22              
2Australian Research Council Centre of Excellence for Coherent X-ray Science, The University of Melbourne, Melbourne, Vic. 3010, Australia, ou_persistent22              
3Electron Microscopy Unit, Bio21 Molecular Science and Biotechnology Institute, The University of Melbourne, Melbourne, Vic. 3010, Australia, ou_persistent22              
4Department of Computer Science and Software Engineering, The University of Melbourne, Vic. 3010, Australia, ou_persistent22              
5Department of Biochemistry, La Trobe University, Bundoora, Vic. 3086, Australia, ou_persistent22              
6Center for Cellular Imaging and NanoAnalytics (C-CINA), Biozentrum, University of Basel, 4058 Basel, Switzerland, ou_persistent22              
7Melbourne University Virtual Environments for Simulation, The University of Melbourne, Vic. 3010, Australia, ou_persistent22              
8School of Physics, The University of Melbourne, Vic. 3010, Australia, ou_persistent22              

内容説明

表示:
非表示:
キーワード: Electron tomography; Denoising; Plasmodium; Non-linear anisotropic diffusion filtering
 要旨: Electron tomography produces highly magnified 3D image volumes useful for investigating the structure and function of cellular components. Image quality is degraded by multiple scattering events and quantum noise, which depend on the angle at which individual tilt projections are collected. We have adapted a biomedical imaging approach to improve image quality by enhancing individual tilt projections prior to volumetric reconstruction. Specifically, we have developed a family of non-linear anisotropic diffusion (NAD) filters parameterized by the tilt angle. We give a quantitative and qualitative evaluation of our pre-processing approach and the NAD filter. We show an improvement in the reconstructed volumes for tomograms generated from both plastic-embedded and cryo-stabilized samples of malaria parasite-infected erythrocytes.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2012-05-162012-02-292012-05-252012-06-052012-10-01
 出版の状態: 出版
 ページ: 11
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1016/j.jsb.2012.05.019
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Journal of Structural Biology
  省略形 : J. Struct. Biol.
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: San Diego, CA : Elsevier
ページ: - 巻号: 180 (1) 通巻号: - 開始・終了ページ: 132 - 142 識別子(ISBN, ISSN, DOIなど): ISSN: 1047-8477
CoNE: https://pure.mpg.de/cone/journals/resource/954922650160