English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  A new double-barrelled, ionophore-based microelectrode for chloride ions

Kondo, Y., Bührer, T., Frömter, E., & Simon, W. (1989). A new double-barrelled, ionophore-based microelectrode for chloride ions. Pflügers Archiv: European Journal of Physiology, 414(6), 663-668. doi:10.1007/BF00582133.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Kondo, Y.1, 2, Author
Bührer, T.2, Author
Frömter, Eberhard1, 3, Author           
Simon, W.2, Author
Affiliations:
1Zentrum der Physiologie, Klinikum der Johann Wolfgang Goethe-Universität, Frankfurt, Federal Republic of Germany, ou_persistent22              
2Laboratorium für Organische Chemie, Eidgenössische Technische Hochschule, Universitätsstrasse 16, CH-8092, Zürich, Switzerland, ou_persistent22              
3Department of Physiology, Max Planck Institute of Biophysics, Max Planck Society, ou_2068297              

Content

show
hide
Free keywords: Chloride microelectrode; Porphin manganese(III) chloride; S3 segment of rabbit renal proximal tubule; Intracellular chloride activity; Residual chloride
 Abstract: A new Cl selective microelectrode based on the ionophore 5,10,15,20-tetraphenyl-21H,23H-porphin manganese(III) chloride is presented which discriminates better against HCO3 and several organic anions than electrodes containing the Corning 477913 ion-eschanger. Using a redesigned construction procedure, fine-tip double-barrelled microelectrodes were produced which had slopes of −52.4±0.6 mV (SE,n=24), resistances of about 7·1011 Ω and a selectivity coefficient log potCl, HCO3 of −1.40±0.03. Some electrodes showed a small unexplained sensitivity to pH>7.6. When used to puncture cells of isolated S3 segments of rabbit renal proximal tubule during perfusion with HCO3 Ringer solution, the electrodes gave a membrane potential of −69.8±1.5 mV and an intracellular Cl activity, [Cl]i, of 35.3±2.6 mmol/l. Upon switching bath and lumen perfusions to Cl-free solutions the “residual” [Cl]i dropped to 1.20±0.03 mmol/l, while in similar measurements with ion-exchanger electrodes the “residual” [Cl]i dropped only to 10.9±0.5 mmol/l. These observations demonstrate the superiority of the new electrode and prove that previously determined high [Cl]i values in Cl-free ambient solutions reflect interference problems rather than non-exchangeable intracellular chloride.

Details

show
hide
Language(s): eng - English
 Dates: 1989-04-241989-05-241989-09-01
 Publication Status: Issued
 Pages: 6
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1007/BF00582133
PMID: 2813044
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Pflügers Archiv: European Journal of Physiology
  Other : Pflügers Arch. Europ. J. Physiol.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Heidelberg : Springer-Verlag
Pages: - Volume / Issue: 414 (6) Sequence Number: - Start / End Page: 663 - 668 Identifier: ISSN: 0031-6768