  Isotope ratio infrared spectroscopy analysis of water samples without memory effects

De Graaf, S., Vonhof, H. B., Levy, E. J., Markowska, M., & Haug, G. H. (2021). Isotope ratio infrared spectroscopy analysis of water samples without memory effects. Rapid Communications in Mass Spectrometry, 35(8): e9055. doi:10.1002/rcm.9055.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Hybrid

Creators

show
hide
 Creators:
De Graaf, Stefan1, Author           
Vonhof, Hubert B.1, Author           
Levy, Elan J.1, Author           
Markowska, Monika1, Author           
Haug, Gerald H.1, Author           
Affiliations:
1Climate Geochemistry, Max Planck Institute for Chemistry, Max Planck Society, ou_2237635              

Content

show
hide
Free keywords: -
 Abstract:
Rationale

Since their introduction more than a decade ago, isotope ratio infrared spectroscopy (IRIS) systems have rapidly become the standard for oxygen (δ18O) and hydrogen (δ2H) isotope analysis of water samples. An important disadvantage of IRIS systems is the well‐documented sample‐to‐sample memory effect, which requires each sample to be analyzed multiple times before the desired accuracy is reached, lengthening analysis times and driving up the costs of analyses.
Methods

We present an adapted set‐up and calculation protocol for fully automated analysis of water samples using a Picarro L2140‐i cavity ring‐down spectroscopy instrument. The adaptation removes memory effects by use of a continuously moisturized nitrogen carrier gas. Water samples of 0.5 μL are measured on top of the water vapor background, after which isotope ratios are calculated by subtraction of the background from the sample peaks.
Results

With this new technique, single injections of water samples have internal precisions (1σ) below 0.05‰ for δ18O values and 0.1‰ for δ2H values, regardless of the isotope ratio of the previous sample. Precision is worse, however, when the isotope difference between the sample and background water is too large (i.e., exceeding approximately 9‰ for δ18O values and 70‰ for δ2H values). Isotope ratios show negligible drift across the four weeks within which the experiments were performed. The single‐injection 1σ precision for 17O excess (Δ′17O) determined with this method is 60 per meg.
Conclusions

Our experiments demonstrate that by removing sample‐to‐sample memory effects with a moisturized carrier gas, the time for measurement of δ18O and δ2H values using an IRIS system can be reduced markedly without compromising the analytical precision and accuracy. Thorough replication is needed to achieve sufficiently low uncertainties for Δ′17O.

Details

show
hide
Language(s):
 Dates: 2021-02-01
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/rcm.9055
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Rapid Communications in Mass Spectrometry
  Other : Rapid Commun. Mass Spectrom.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York, NY : John Wiley & Sons
Pages: 12 Volume / Issue: 35 (8) Sequence Number: e9055 Start / End Page: - Identifier: ISSN: 0951-4198
CoNE: https://pure.mpg.de/cone/journals/resource/954925574961