English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Sensitivity and resolution improvement for in-vivo magnetic resonance current density imaging (MRCDI) of the human brain

Göksu, C., Scheffler, K., Gregersen, F., Eroglu, H., Heule, R., Siebner, H., et al. (2021). Sensitivity and resolution improvement for in-vivo magnetic resonance current density imaging (MRCDI) of the human brain. Magnetic Resonance in Medicine, 86(6), 3131-3146. doi:10.1002/mrm.28944.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Not specified

Creators

show
hide
 Creators:
Göksu, C1, 2, Author           
Scheffler, K1, 2, Author           
Gregersen, F, Author
Eroglu, HH, Author
Heule, R1, 2, Author           
Siebner , HR, Author
Hanson, LG, Author
Thielscher, A, Author           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose: Magnetic resonance current density imaging (MRCDI) combines MR brain imaging with the injection of time-varying weak currents (1-2 mA) to assess the current flow pattern in the brain. However, the utility of MRCDI is still hampered by low measurement sensitivity and poor image quality. Methods: We recently introduced a multi-gradient-echo-based MRCDI approach that has the hitherto best documented efficiency. We now advanced our MRCDI approach in three directions and performed phantom and in-vivo human brain experiments for validation: First, we verified the importance of enhanced spoiling and optimize it for imaging of the human brain. Second, we improved the sensitivity and spatial resolution by using acquisition weighting. Third, we added navigators as a quality control measure for tracking physiological noise. Combining these advancements, we tested our optimized MRCDI method by using 1 mA transcranial electrical stimulation (TES) currents injected via two different electrode montages in five subjects. Results: For a session duration of 4:20 min, the new MRCDI method was able to detect magnetic field changes caused by the TES current flow at a sensitivity level of 84 pT, representing in a twofold increase relative to our original method. Comparing both methods to current flow simulations based on personalized head models demonstrated a consistent increase in the coefficient of determination of ∆R2=0.12 for the current-induced magnetic fields and ∆R2=0.22 for the current flow reconstructions. Interestingly, some of the simulations still clearly deviated from the measurements despite of the strongly improved measurement quality. This suggests that MRCDI can reveal useful information for the improvement of head models used for current flow simulations. Conclusion: The advanced method strongly improves the sensitivity and robustness of MRCDI and is an important step from proof-of-concept studies towards a broader application of MRCDI in clinical and basic neuroscience research.

Details

show
hide
Language(s):
 Dates: 2021-082021-12
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.28944
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 86 (6) Sequence Number: - Start / End Page: 3131 - 3146 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149