Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Sensitivity and resolution improvement for in-vivo magnetic resonance current density imaging (MRCDI) of the human brain

Göksu, C., Scheffler, K., Gregersen, F., Eroglu, H., Heule, R., Siebner, H., et al. (2021). Sensitivity and resolution improvement for in-vivo magnetic resonance current density imaging (MRCDI) of the human brain. Magnetic Resonance in Medicine, 86(6), 3131-3146. doi:10.1002/mrm.28944.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:
Keine Angabe

Urheber

einblenden:
ausblenden:
 Urheber:
Göksu, C1, 2, Autor           
Scheffler, K1, 2, Autor           
Gregersen, F, Autor
Eroglu, HH, Autor
Heule, R1, 2, Autor           
Siebner , HR, Autor
Hanson, LG, Autor
Thielscher, A, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Purpose: Magnetic resonance current density imaging (MRCDI) combines MR brain imaging with the injection of time-varying weak currents (1-2 mA) to assess the current flow pattern in the brain. However, the utility of MRCDI is still hampered by low measurement sensitivity and poor image quality. Methods: We recently introduced a multi-gradient-echo-based MRCDI approach that has the hitherto best documented efficiency. We now advanced our MRCDI approach in three directions and performed phantom and in-vivo human brain experiments for validation: First, we verified the importance of enhanced spoiling and optimize it for imaging of the human brain. Second, we improved the sensitivity and spatial resolution by using acquisition weighting. Third, we added navigators as a quality control measure for tracking physiological noise. Combining these advancements, we tested our optimized MRCDI method by using 1 mA transcranial electrical stimulation (TES) currents injected via two different electrode montages in five subjects. Results: For a session duration of 4:20 min, the new MRCDI method was able to detect magnetic field changes caused by the TES current flow at a sensitivity level of 84 pT, representing in a twofold increase relative to our original method. Comparing both methods to current flow simulations based on personalized head models demonstrated a consistent increase in the coefficient of determination of ∆R2=0.12 for the current-induced magnetic fields and ∆R2=0.22 for the current flow reconstructions. Interestingly, some of the simulations still clearly deviated from the measurements despite of the strongly improved measurement quality. This suggests that MRCDI can reveal useful information for the improvement of head models used for current flow simulations. Conclusion: The advanced method strongly improves the sensitivity and robustness of MRCDI and is an important step from proof-of-concept studies towards a broader application of MRCDI in clinical and basic neuroscience research.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2021-082021-12
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/mrm.28944
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York : Wiley-Liss
Seiten: - Band / Heft: 86 (6) Artikelnummer: - Start- / Endseite: 3131 - 3146 Identifikator: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149