English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  BOLD sensitivity and vessel size specificity along CPMG and GRASE echo trains

Scheffler, K., Engelmann, J., & Heule, R. (2021). BOLD sensitivity and vessel size specificity along CPMG and GRASE echo trains. Magnetic Resonance in Medicine, 86(4), 2076-2083. doi:10.1002/mrm.28871.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Scheffler, K1, 2, Author           
Engelmann, J1, 2, Author           
Heule, R1, 2, Author           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose: To assess the vessel size specificity and sensitivity of rapid CPMG and GRASE for functional BOLD imaging for different echo train lengths, echo spacings, field strength, and refocusing flip angle schemes. In addition, the behavior of signals acquired before and after the refocusing time points is analyzed.

Methods: Evolution of magnetization within a network of artificial cylinders is simulated with Monte Carlo methods for all relevant coherence pathways. In addition, measurements on microspheres were performed to confirm some of the theoretical results.

Results: For reduced refocusing flip angles, the peak of the vessel size sensitivity curve is shifting toward larger radii with increasing echo time. Furthermore, the BOLD-related signal change along the echo train depends on the chosen refocusing flip angle scheme and in general does not follow corresponding echo amplitudes.

Conclusion: CPMG or GRASE can be used with low refocusing flip angles without significant loss of sensitivity to BOLD. The evolution of BOLD signal changes along the echo train can be used to design optimal k-space reordering schemes. Signals acquired before or after the spin echo time point show contributions from larger vessels similar to gradient echo sequences. Short echo spacing (time between refocusing pulses) suppresses gradient echo-related contributions from larger vessels, whereas the spin echo-related contribution from small vessels remains constant and is independent of the echo spacing.

Details

show
hide
Language(s):
 Dates: 2021-052021-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.28871
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 86 (4) Sequence Number: - Start / End Page: 2076 - 2083 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149