English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Open birdcage coil for head imaging at 7T

Nikulin, A., Vignaud, A., Avdievich, N., Berrahou, D., de Rosny, J., & Ourir, A. (2021). Open birdcage coil for head imaging at 7T. Magnetic Resonance in Medicine, 86(4), 2290-2300. doi:10.1002/mrm.28845.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Nikulin, AV, Author
Vignaud, A, Author
Avdievich, NI1, 2, Author           
Berrahou, D, Author
de Rosny, J, Author
Ourir, A, Author
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: Purpose: To theoretically describe, design, and test the new geometry of the birdcage coil for 7 Tesla anatomical brain imaging, which includes a large window on top, without deliberately jeopardizing its homogeneity and efficiency. This opencage will not only improve patient comfort but also enable the volunteer to follow functional MRI stimuli. This design could also facilitate the tracking of patient compliance and enable better correction of the movement.

Methods: Via the transfer matrix approach, a birdcage-like coil with a nonperiodic distribution of rungs is constructed with optimized currents in the coil rungs. Subsequently, the coil is adjusted in full-wave simulations. Then, the coil is assembled, fine-tuned, and matched on the bench. Finally, these results are confirmed experimentally on a phantom and in vivo.

Results: Indeed, the computed isolation of -14.9 dB between the feeding ports of the coil and the symmetry of the circular polarized mode pattern transmit RF magnetic field ( B+1

) showed that the coil was properly optimized. An experimental assessment of the developed coil showed competitive transmit efficiency and coverage compared with the conventional birdcage coil of similar size.

Conclusion: The proposed opencage coil can be designed and work without a dramatic drop of performance in terms of the B+1
field homogeneity, transmit efficiency ( (B+1) / √Pref ), peak local specific absorption rate ( SAR10g ) and SAR efficiency ( (B+1) / √SAR10g ).

Details

show
hide
Language(s):
 Dates: 2021-062021-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.28845
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 86 (4) Sequence Number: - Start / End Page: 2290 - 2300 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149