  Physical correction model for automatic correction of intensity non-uniformity in magnetic resonance imaging.

Leger, S., Löck, S., Hietschold, V., Haase, R., Böhme, H. J., & Abolmaali, N. (2017). Physical correction model for automatic correction of intensity non-uniformity in magnetic resonance imaging. Physics and Imaging in Radiation Oncology, 4, 32-38. doi:10.1016/j.phro.2017.11.003.

Item is

Files

show Files

Locators

show

Creators

hide
 Creators:
Leger, Stefan1, Author
Löck, Steffen, Author
Hietschold, Volker1, Author
Haase, Robert1, Author           
Böhme, Hans Joachim1, Author
Abolmaali, Nasreddin, Author
Affiliations:
1Max Planck Institute for Molecular Cell Biology and Genetics, Max Planck Society, ou_2340692              

Content

hide
Free keywords: -
 Abstract: Background and purpose: Magnetic resonance imaging (MRI) plays an important role in the field of MR-guided radiotherapy or personalised radiation oncology. The application of quantitative image analyses like radiomics as well as automated tissue characterisation is frequently disturbed by the effect of intensity non-uniformity. We present a novel fully automated physical correction model (PCM) for the reduction of intensity non-uniformity. Materials and methods: The proposed algorithm is based on a 3D physically motivated correction model, which maximises the image information expressed by the Shannon entropy. The PCM was evaluated using the coefficient of variation (cv) on 176 MRI datasets of the human brain and abdomen acquired on 1.5 Tesla and 3 Tesla MR scanners. The resulting cv was compared to the cv of the original images and to the results of the established N4 algorithm. Results: The PCM algorithm significantly improved the image quality of all considered 1.5 and 3.0 Tesla MR scans compared to the original images (p <.01). Furthermore, the PCM outperformed or competed with the N4 algorithm in terms of image quality. Additionally, the PCM approach preserved the tissue signal of different tissue types due to smooth correction gradients. Conclusion: The proposed PCM algorithm led to a significantly improved image quality compared to the originally acquired images, suggesting that it is applicable to the correction of MRI data. Thus it may help to reduce intensity non-uniformity which is an important step for advanced image analysis.

Details

hide
Language(s):
 Dates: 2017-01-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1016/j.phro.2017.11.003
Other: cbg-8157
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

hide
Title: Physics and Imaging in Radiation Oncology
  Other : Physics and Imaging in Radiation Oncology
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 4 Sequence Number: - Start / End Page: 32 - 38 Identifier: -